Expert Guidance Monday-Friday, 6:30am-4pm PST. Call Now! Request a Quote Click Here!

SKU: RKI01-65-2424RK

RKI M-Series Low Cost H2S Sensor/Transmitter 65-2424RK

$369.64

Ships in 6 - 8 weeks

Description

The RKI M-Series H2S Sensor/Transmitter (65-2424RK) is a cost-effective 4-20 mA fixed-point transmitter for Hydrogen Sulfide detection. The water- and dust-resistant plastic enclosure protects electronics from mechanical abuse and corrosion, making it suitable for indoor use and semi-enclosed areas such as utility vaults, treatment plants, and loading docks.

Please call Customer Service at 800.829.9580 if you have questions in choosing the correct product.

Operates from 24 VDC (11-30 VDC input range) and outputs a standard 4-20 mA signal compatible with the RKI Beacon 110, Beacon 200, Beacon 410, or Beacon 800 controllers and most PLCs and DCS systems.

Applications: Water & wastewater treatment plants, Pulp & paper mills, Gas and electric utilities, Parking garages, Manufacturing facilities, Loading docks

Key Features:

  • Hydrogen Sulfide (H2S) detection; 4-20 mA output
  • Water- and dust-resistant housing
  • Long-life H2S sensors: 2+ years typical
  • Single-person field calibration with voltmeter, screwdriver, and cal gas
  • Compact design; competitively priced
  • Made in the USA

Specification Sheet: Specification Sheet

Manual: Manual

Part Number:
65-2424RK

Frequently Asked Questions

What is the RKI M-Series H2S transmitter used for?

The M-Series H2S (65-2424RK) provides 4-20 mA hydrogen sulfide detection for fixed monitoring at water and wastewater treatment plants, pulp and paper mills, gas and electric utilities, manufacturing facilities, and loading docks. Its sealed, water-resistant housing withstands challenging industrial environments.

What power supply and output does the M-Series H2S use?

The M-Series H2S operates from 24 VDC (11-30 VDC) and delivers a standard 4-20 mA output, compatible with the RKI Beacon 110, Beacon 200, Beacon 410, or Beacon 800 controllers and most PLCs and DCS systems for straightforward system integration.

How is the M-Series H2S calibrated in the field?

Calibration requires a voltmeter, a screwdriver, and H2S calibration gas. Zero and span are set via potentiometers on the amplifier board, and test jacks allow voltmeter monitoring of the 100-500 mV sensor response during the span procedure. The process is designed for one technician without specialized equipment.

How long do M-Series H2S sensors last?

H2S sensors in the M-Series are rated for a typical service life of 2 to 3 years. PK Safety stocks replacement sensors for scheduled preventive maintenance to minimize downtime in fixed H2S monitoring applications.

Does PK Safety service the M-Series H2S transmitter?

Yes. As an RKI Factory Authorized Service Center, PK Safety provides calibration, sensor replacement, and technical support for the M-Series H2S. Call 800.829.9580 to order sensors, calibration gas, or schedule instrument service.

Related Searches
Fixed Gas Detectors, Gas Detection

Read more

The RKI M-Series H2S Sensor/Transmitter (65-2424RK) is a cost-effective 4-20 mA fixed-point transmitter for Hydrogen Sulfide detection. The water- and dust-resistant plastic enclosure protects electronics from mechanical abuse and corrosion, making it suitable for indoor use and semi-enclosed areas such as utility vaults, treatment plants, and loading docks.

Please call Customer Service at 800.829.9580 if you have questions in choosing the correct product.

Operates from 24 VDC (11-30 VDC input range) and outputs a standard 4-20 mA signal compatible with the RKI Beacon 110, Beacon 200, Beacon 410, or Beacon 800 controllers and most PLCs and DCS systems.

Applications: Water & wastewater treatment plants, Pulp & paper mills, Gas and electric utilities, Parking garages, Manufacturing facilities, Loading docks

Key Features:

  • Hydrogen Sulfide (H2S) detection; 4-20 mA output
  • Water- and dust-resistant housing
  • Long-life H2S sensors: 2+ years typical
  • Single-person field calibration with voltmeter, screwdriver, and cal gas
  • Compact design; competitively priced
  • Made in the USA

Specification Sheet: Specification Sheet

Manual: Manual

Part Number:
65-2424RK

Frequently Asked Questions

What is the RKI M-Series H2S transmitter used for?

The M-Series H2S (65-2424RK) provides 4-20 mA hydrogen sulfide detection for fixed monitoring at water and wastewater treatment plants, pulp and paper mills, gas and electric utilities, manufacturing facilities, and loading docks. Its sealed, water-resistant housing withstands challenging industrial environments.

What power supply and output does the M-Series H2S use?

The M-Series H2S operates from 24 VDC (11-30 VDC) and delivers a standard 4-20 mA output, compatible with the RKI Beacon 110, Beacon 200, Beacon 410, or Beacon 800 controllers and most PLCs and DCS systems for straightforward system integration.

How is the M-Series H2S calibrated in the field?

Calibration requires a voltmeter, a screwdriver, and H2S calibration gas. Zero and span are set via potentiometers on the amplifier board, and test jacks allow voltmeter monitoring of the 100-500 mV sensor response during the span procedure. The process is designed for one technician without specialized equipment.

How long do M-Series H2S sensors last?

H2S sensors in the M-Series are rated for a typical service life of 2 to 3 years. PK Safety stocks replacement sensors for scheduled preventive maintenance to minimize downtime in fixed H2S monitoring applications.

Does PK Safety service the M-Series H2S transmitter?

Yes. As an RKI Factory Authorized Service Center, PK Safety provides calibration, sensor replacement, and technical support for the M-Series H2S. Call 800.829.9580 to order sensors, calibration gas, or schedule instrument service.

Related Searches
Fixed Gas Detectors, Gas Detection

Specifications

  • Gas Type
    Hydrogen Sulfide (H2S)
  • Product Weight (lbs.)
    2
  • Height (in.)
    4
  • Length (in.)
    1.5
  • Width (in.)
    2.5
  • Country of Origin
    US

Reviews

Keep your team protected & compliant!

  • Expert guidance tailored to your specific needs
  • Access responsive customer support when you need it
  • Enjoy fast shipping directly to your location
  • Benefit from extensive industry knowledge—75+ years of experience
  • In-house gas detection calibration & repair services available
The RKI Instruments M-Series Low Cost H2S Sensor/Transmitter 65-2424RK is a compact rectangular white box with a circular top opening, a black cable, and four corner screws—ideal for affordable H2S detection.
RKI Instruments

RKI M-Series Low Cost H2S Sensor/Transmitter 65-2424RK

$369.64

The RKI M-Series H2S Sensor/Transmitter (65-2424RK) is a cost-effective 4-20 mA fixed-point transmitter for Hydrogen Sulfide detection. The water- and dust-resistant plastic enclosure protects electronics from mechanical abuse and corrosion, making it suitable for indoor use and semi-enclosed areas such as utility vaults, treatment plants, and loading docks.

Please call Customer Service at 800.829.9580 if you have questions in choosing the correct product.

Operates from 24 VDC (11-30 VDC input range) and outputs a standard 4-20 mA signal compatible with the RKI Beacon 110, Beacon 200, Beacon 410, or Beacon 800 controllers and most PLCs and DCS systems.

Applications: Water & wastewater treatment plants, Pulp & paper mills, Gas and electric utilities, Parking garages, Manufacturing facilities, Loading docks

Key Features:

Specification Sheet: Specification Sheet

Manual: Manual

Part Number:
65-2424RK

Frequently Asked Questions

What is the RKI M-Series H2S transmitter used for?

The M-Series H2S (65-2424RK) provides 4-20 mA hydrogen sulfide detection for fixed monitoring at water and wastewater treatment plants, pulp and paper mills, gas and electric utilities, manufacturing facilities, and loading docks. Its sealed, water-resistant housing withstands challenging industrial environments.

What power supply and output does the M-Series H2S use?

The M-Series H2S operates from 24 VDC (11-30 VDC) and delivers a standard 4-20 mA output, compatible with the RKI Beacon 110, Beacon 200, Beacon 410, or Beacon 800 controllers and most PLCs and DCS systems for straightforward system integration.

How is the M-Series H2S calibrated in the field?

Calibration requires a voltmeter, a screwdriver, and H2S calibration gas. Zero and span are set via potentiometers on the amplifier board, and test jacks allow voltmeter monitoring of the 100-500 mV sensor response during the span procedure. The process is designed for one technician without specialized equipment.

How long do M-Series H2S sensors last?

H2S sensors in the M-Series are rated for a typical service life of 2 to 3 years. PK Safety stocks replacement sensors for scheduled preventive maintenance to minimize downtime in fixed H2S monitoring applications.

Does PK Safety service the M-Series H2S transmitter?

Yes. As an RKI Factory Authorized Service Center, PK Safety provides calibration, sensor replacement, and technical support for the M-Series H2S. Call 800.829.9580 to order sensors, calibration gas, or schedule instrument service.