Expert Guidance Monday-Friday, 6:30am-4pm PST. Call Now! Request a Quote Click Here!

SKU: RKI01-72-2110RK

RKI Beacon 110 Single Channel Wall Mount Fixed Systems Controller

$1,546.15

Ships in 4 - 6 weeks

Description

The RKI Beacon 110 Single Channel Wall Mount Controller is a plug-and-play fixed gas detection controller for a single monitoring point. Mount an RKI Direct Connect, S2, or M2A-XL sensor wherever the target gas is likely to accumulate, and the Beacon 110 manages alarming and relay outputs from a centralized, easy-to-read panel. It accepts any 4-20 mA transmitter (2-wire or 3-wire, 24 VDC), so it integrates with the full range of RKI sensor families as well as third-party transmitters. Fixed systems such as the Beacon 110 are used for perimeter monitoring, with detection heads typically mounted and wired around the unit process area.

The Beacon 110 ships in a NEMA 4X weather-tight enclosure that complies with lockout/tagout standards and can be fully secured. An external reset switch silences the alarm from outside the controller housing. A wall mounting kit is included.

Applications: Petrochemical plants, Refineries, Water & wastewater treatment plants, Pulp & paper mills, Gas, telephone & electric utilities, Parking garages, Manufacturing facilities, Steel, Automotive, HVAC

Key Features:

  • Low-cost single-channel fixed monitoring solution
  • Ships complete with wall mounting kit
  • Controller only — sensors ordered separately
  • Indoor or outdoor installation (NEMA 4X enclosure)
  • 115/220 VAC standard (call for 24 VDC option)
  • Accepts RKI LEL/O2/H2S/CO Direct Connect sensors
  • Accepts any 4-20 mA transmitter (2 or 3 wire)
  • Audible alarm with external reset button
  • Two programmable alarm levels
  • Built-in trouble alarm with relay
  • Relay rating 10 amps, form C
  • Provides 4-20 mA output
  • Optional battery backup available (battery charger models)

Ordering Information: When ordering a Beacon 110 system, specify: (1) the controller model (-01 for battery charger, -02 or -03 for strobe); (2) a detector assembly from one of the compatible sensor families: Direct Connect (LEL, O2, H2S, CO), S2 Series, M2A-XL Series, T2A Series, T3A Series, VOC Pro, Air Alert, GD-70D, or GD-K88AI; and (3) an optional battery backup assembly if the battery charger model is ordered.

Note: Fixed system pricing covers equipment only and does not include factory start-up or training. Contact PK Safety at 800.829.9580 for start-up support quotations or assistance configuring a system.

Specification Sheet:

Specification Sheet

Manual:

Manual

Part Numbers:
72-2110RK - single channel controller (no sensor)
72-2110RK-01 - single channel controller with battery charger (no sensor or back-up battery)
72-2110-11C - single channel controller with horn and small clear strobe light (no sensor)
72-2110-12C - single channel controller with battery charger, horn, and clear red strobe light (no sensor)

Related Searches
Controllers, Fixed Gas Detectors, Gas Detection

Frequently Asked Questions

What sensors are compatible with the Beacon 110?

The Beacon 110 accepts RKI Direct Connect sensors for LEL, O2, H2S, and CO, and also works with the S2, M2A-XL, T2A, T3A, VOC Pro, Air Alert, GD-70D, and GD-K88AI sensor families. It accepts any industry-standard 4-20 mA transmitter in 2-wire or 3-wire configuration, making it compatible with a wide range of third-party transmitters as well.

Does the Beacon 110 include sensors?

No. The Beacon 110 is a controller only. You must order the detection head—Direct Connect, S2, M2A-XL, or equivalent—separately. Specify the target gas when ordering so the correct sensor assembly is selected. Contact PK Safety at 800.829.9580 for help configuring a complete system.

Can the Beacon 110 be installed outdoors?

Yes. The Beacon 110 is housed in a NEMA 4X enclosure that provides a weather-tight seal suitable for both indoor and outdoor installations. The enclosure also meets lockout/tagout requirements and can be fully secured with a padlock to restrict unauthorized access.

What power supply does the Beacon 110 require?

The standard Beacon 110 operates on 115 or 220 VAC. For applications requiring a 24 VDC power option, contact PK Safety at 800.829.9580. Battery backup assemblies are available for models ordered with the built-in battery charger option (-01, -12C).

Does the Beacon 110 include factory start-up support?

Fixed system pricing covers equipment only. Factory start-up and on-site training are available separately. PK Safety is an RKI Factory Authorized Service Center and can connect you with start-up support—contact us at 800.829.9580 to discuss your installation requirements.

Read more

The RKI Beacon 110 Single Channel Wall Mount Controller is a plug-and-play fixed gas detection controller for a single monitoring point. Mount an RKI Direct Connect, S2, or M2A-XL sensor wherever the target gas is likely to accumulate, and the Beacon 110 manages alarming and relay outputs from a centralized, easy-to-read panel. It accepts any 4-20 mA transmitter (2-wire or 3-wire, 24 VDC), so it integrates with the full range of RKI sensor families as well as third-party transmitters. Fixed systems such as the Beacon 110 are used for perimeter monitoring, with detection heads typically mounted and wired around the unit process area.

The Beacon 110 ships in a NEMA 4X weather-tight enclosure that complies with lockout/tagout standards and can be fully secured. An external reset switch silences the alarm from outside the controller housing. A wall mounting kit is included.

Applications: Petrochemical plants, Refineries, Water & wastewater treatment plants, Pulp & paper mills, Gas, telephone & electric utilities, Parking garages, Manufacturing facilities, Steel, Automotive, HVAC

Key Features:

  • Low-cost single-channel fixed monitoring solution
  • Ships complete with wall mounting kit
  • Controller only — sensors ordered separately
  • Indoor or outdoor installation (NEMA 4X enclosure)
  • 115/220 VAC standard (call for 24 VDC option)
  • Accepts RKI LEL/O2/H2S/CO Direct Connect sensors
  • Accepts any 4-20 mA transmitter (2 or 3 wire)
  • Audible alarm with external reset button
  • Two programmable alarm levels
  • Built-in trouble alarm with relay
  • Relay rating 10 amps, form C
  • Provides 4-20 mA output
  • Optional battery backup available (battery charger models)

Ordering Information: When ordering a Beacon 110 system, specify: (1) the controller model (-01 for battery charger, -02 or -03 for strobe); (2) a detector assembly from one of the compatible sensor families: Direct Connect (LEL, O2, H2S, CO), S2 Series, M2A-XL Series, T2A Series, T3A Series, VOC Pro, Air Alert, GD-70D, or GD-K88AI; and (3) an optional battery backup assembly if the battery charger model is ordered.

Note: Fixed system pricing covers equipment only and does not include factory start-up or training. Contact PK Safety at 800.829.9580 for start-up support quotations or assistance configuring a system.

Specification Sheet:

Specification Sheet

Manual:

Manual

Part Numbers:
72-2110RK - single channel controller (no sensor)
72-2110RK-01 - single channel controller with battery charger (no sensor or back-up battery)
72-2110-11C - single channel controller with horn and small clear strobe light (no sensor)
72-2110-12C - single channel controller with battery charger, horn, and clear red strobe light (no sensor)

Related Searches
Controllers, Fixed Gas Detectors, Gas Detection

Frequently Asked Questions

What sensors are compatible with the Beacon 110?

The Beacon 110 accepts RKI Direct Connect sensors for LEL, O2, H2S, and CO, and also works with the S2, M2A-XL, T2A, T3A, VOC Pro, Air Alert, GD-70D, and GD-K88AI sensor families. It accepts any industry-standard 4-20 mA transmitter in 2-wire or 3-wire configuration, making it compatible with a wide range of third-party transmitters as well.

Does the Beacon 110 include sensors?

No. The Beacon 110 is a controller only. You must order the detection head—Direct Connect, S2, M2A-XL, or equivalent—separately. Specify the target gas when ordering so the correct sensor assembly is selected. Contact PK Safety at 800.829.9580 for help configuring a complete system.

Can the Beacon 110 be installed outdoors?

Yes. The Beacon 110 is housed in a NEMA 4X enclosure that provides a weather-tight seal suitable for both indoor and outdoor installations. The enclosure also meets lockout/tagout requirements and can be fully secured with a padlock to restrict unauthorized access.

What power supply does the Beacon 110 require?

The standard Beacon 110 operates on 115 or 220 VAC. For applications requiring a 24 VDC power option, contact PK Safety at 800.829.9580. Battery backup assemblies are available for models ordered with the built-in battery charger option (-01, -12C).

Does the Beacon 110 include factory start-up support?

Fixed system pricing covers equipment only. Factory start-up and on-site training are available separately. PK Safety is an RKI Factory Authorized Service Center and can connect you with start-up support—contact us at 800.829.9580 to discuss your installation requirements.

Specifications

  • MPN
    72-2110RK
  • Product Weight (lbs.)
    6
  • Height (in.)
    10.5
  • Length (in.)
    6.3
  • Width (in.)
    8.5
  • Country of Origin
    US

Reviews

Keep your team protected & compliant!

  • Expert guidance tailored to your specific needs
  • Access responsive customer support when you need it
  • Enjoy fast shipping directly to your location
  • Benefit from extensive industry knowledge—75+ years of experience
  • In-house gas detection calibration & repair services available
A PK Safety Supply RKI Beacon 110 Single Channel Wall Mount Fixed Systems Controller, in gray and red, is mounted on a white brick wall. This gas monitor is equipped with a digital display that clearly indicates gas levels. At the bottom, two black connectors are neatly integrated into the wall mount controller for seamless operation.
RKI Instruments

RKI Beacon 110 Single Channel Wall Mount Fixed Systems Controller

From $1,546.15

The RKI Beacon 110 Single Channel Wall Mount Controller is a plug-and-play fixed gas detection controller for a single monitoring point. Mount an RKI Direct Connect, S2, or M2A-XL sensor wherever the target gas is likely to accumulate, and the Beacon 110 manages alarming and relay outputs from a centralized, easy-to-read panel. It accepts any 4-20 mA transmitter (2-wire or 3-wire, 24 VDC), so it integrates with the full range of RKI sensor families as well as third-party transmitters. Fixed systems such as the Beacon 110 are used for perimeter monitoring, with detection heads typically mounted and wired around the unit process area.

The Beacon 110 ships in a NEMA 4X weather-tight enclosure that complies with lockout/tagout standards and can be fully secured. An external reset switch silences the alarm from outside the controller housing. A wall mounting kit is included.

Applications: Petrochemical plants, Refineries, Water & wastewater treatment plants, Pulp & paper mills, Gas, telephone & electric utilities, Parking garages, Manufacturing facilities, Steel, Automotive, HVAC

Key Features:

Ordering Information: When ordering a Beacon 110 system, specify: (1) the controller model (-01 for battery charger, -02 or -03 for strobe); (2) a detector assembly from one of the compatible sensor families: Direct Connect (LEL, O2, H2S, CO), S2 Series, M2A-XL Series, T2A Series, T3A Series, VOC Pro, Air Alert, GD-70D, or GD-K88AI; and (3) an optional battery backup assembly if the battery charger model is ordered.

Note: Fixed system pricing covers equipment only and does not include factory start-up or training. Contact PK Safety at 800.829.9580 for start-up support quotations or assistance configuring a system.

Specification Sheet:

Specification Sheet

Manual:

Manual

Part Numbers:
72-2110RK - single channel controller (no sensor)
72-2110RK-01 - single channel controller with battery charger (no sensor or back-up battery)
72-2110-11C - single channel controller with horn and small clear strobe light (no sensor)
72-2110-12C - single channel controller with battery charger, horn, and clear red strobe light (no sensor)

Related Searches
Controllers, Fixed Gas Detectors, Gas Detection

Frequently Asked Questions

What sensors are compatible with the Beacon 110?

The Beacon 110 accepts RKI Direct Connect sensors for LEL, O2, H2S, and CO, and also works with the S2, M2A-XL, T2A, T3A, VOC Pro, Air Alert, GD-70D, and GD-K88AI sensor families. It accepts any industry-standard 4-20 mA transmitter in 2-wire or 3-wire configuration, making it compatible with a wide range of third-party transmitters as well.

Does the Beacon 110 include sensors?

No. The Beacon 110 is a controller only. You must order the detection head—Direct Connect, S2, M2A-XL, or equivalent—separately. Specify the target gas when ordering so the correct sensor assembly is selected. Contact PK Safety at 800.829.9580 for help configuring a complete system.

Can the Beacon 110 be installed outdoors?

Yes. The Beacon 110 is housed in a NEMA 4X enclosure that provides a weather-tight seal suitable for both indoor and outdoor installations. The enclosure also meets lockout/tagout requirements and can be fully secured with a padlock to restrict unauthorized access.

What power supply does the Beacon 110 require?

The standard Beacon 110 operates on 115 or 220 VAC. For applications requiring a 24 VDC power option, contact PK Safety at 800.829.9580. Battery backup assemblies are available for models ordered with the built-in battery charger option (-01, -12C).

Does the Beacon 110 include factory start-up support?

Fixed system pricing covers equipment only. Factory start-up and on-site training are available separately. PK Safety is an RKI Factory Authorized Service Center and can connect you with start-up support—contact us at 800.829.9580 to discuss your installation requirements.

Configuration

  • Controller Only
  • Add Battery Charger
  • Add Horn / Clear Strobe Light
  • Add Battery Charger / Horn / Clear Strobe Light
View product