Expert Guidance Monday-Friday, 6:30am-4pm PST. Call Now! Request a Quote Click Here!

SKU: RKI01-72-FA-A-A10-51

RKI Instruments GX-Force Confined Space Kit 72-FA-A-A10-51

$1,731.43

Ships in 1 - 2 weeks

Description

The RKI Instruments GX-Force Confined Space Kit (72-FA-A-A10-51) is a turnkey solution for OSHA-compliant confined space entry programs. Anchored by the GX-Force 4-gas monitor, this kit adds a pre-filled 34-liter calibration gas cylinder, demand flow regulator, tubing, and a padded carrying case. Teams can bump test, calibrate, and begin monitoring straight out of the box without sourcing separate consumables. The GX-Force measures LEL combustibles, oxygen, carbon monoxide, and hydrogen sulfide through a 100-foot internal sample pump on a 30-hour battery.

Applications: Personal monitoring, Confined spaces, Refineries/petrochemical, Utilities, Oil and Gas, Water/wastewater, Fire services, Construction

Kit includes:

  • RKI GX-Force 4-gas monitor (LEL / O₂ / H₂S / CO) with Li-ion battery pack
  • One aluminum 34 L calibration gas cylinder (H₂S/CO/O₂/CH₄ mixture)
  • Demand flow regulator
  • Calibration tubing
  • Padded protective carrying case

Remember to calibrate every six months and regularly perform bump tests.

Note: calibration gas is not returnable. Please check your selection carefully before ordering.

Detection target gas Combustible gas (CH4) Oxygen (O2) Carbon monoxide (CO) Hydrogen sulfide (H2S)
Detection principle Catalytic combustion Electrochemical type Electrochemical type Electrochemical type
Detection range 0 – 100 % LEL 0.0 – 40.0 vol % 0 – 2,000 ppm 0.0 – 200.0 ppm
Resolution 1 % LEL 0.1 vol % 1 ppm 0.1 ppm
Alarm setpoints 1st alarm: 10 % LEL
2nd alarm: 25 % LEL
3rd alarm: 50 % LEL
OVER alarm: 100 % LEL
L alarm: 19.5 vol %
LL alarm: 18.0 vol %
H alarm: 23.5 vol %
OVER alarm: 40.0 vol %
1st alarm: 25 ppm
2nd alarm: 50 ppm
3rd alarm: 1200 ppm
TWA alarm: 25 ppm
STEL alarm: 200 ppm
OVER alarm: 2,000 ppm
1st alarm: 5.0 ppm
2nd alarm: 30.0 ppm
3rd alarm: 100.0 ppm
TWA alarm: 1.0 ppm
STEL alarm: 5.0 ppm
OVER alarm: 200.0 ppm
Response time (T90) Within 30 seconds Within 20 seconds Within 30 seconds Within 30 seconds

Specification Sheet:

Specification Sheet

Quick Reference Guide:

Quick Reference Guide

Manual:

Manual

Data Logger Manual:

Data Logger Manual

Part Number:
72-FA-A-A10-51

Related Searches
Calibration Gas, Confined Space Kits, Confined Space, Gas Detection, Multi-Gas Monitors, Portable Gas Monitors And Detectors, Rki Instruments

Frequently Asked Questions

What is the part number for this confined space kit?

This kit is part number 72-FA-A-A10-51. It includes the RKI GX-Force 4-gas monitor, a 34-liter aluminum calibration gas cylinder (H₂S/CO/O₂/CH₄), a demand flow regulator, calibration tubing, and a padded carrying case.

Why does this kit ship via UPS Ground only?

The 34-liter calibration gas cylinder is a hazardous material (compressed gas) subject to DOT regulations. Ground-only shipping applies regardless of your preferred shipping method, and the calibration gas is non-returnable. Please verify your cylinder gas mixture and quantity before placing the order.

How often should I calibrate the GX-Force?

RKI recommends a bump test (functional gas test) before each day of use and a full calibration at minimum every six months. The 34-liter cylinder included in this kit contains enough gas for multiple calibration cycles. When the cylinder is depleted, replacement calibration gas (part 81-0154RK-04) is available separately from PK Safety.

Does this kit include a wall charger for the GX-Force?

This confined space kit (72-FA-A-A10-51) includes the padded case, calibration gas, regulator, and tubing, but does not include a wall charger. The GX-Force with Case bundle (72-FA-A-A10-50) includes the charger. The 100–240 VAC AC adapter (part 49-0139) is available separately.

Can I use this calibration gas with other RKI monitors?

Yes. The 34 L H₂S/CO/O₂/CH₄ calibration gas mixture in this kit is also the standard four-gas mixture for the GX-3R, GX-3R Pro, GX-2009, and GX-2012. If you operate a mixed fleet, the same cylinder services multiple RKI instruments.

Read more

The RKI Instruments GX-Force Confined Space Kit (72-FA-A-A10-51) is a turnkey solution for OSHA-compliant confined space entry programs. Anchored by the GX-Force 4-gas monitor, this kit adds a pre-filled 34-liter calibration gas cylinder, demand flow regulator, tubing, and a padded carrying case. Teams can bump test, calibrate, and begin monitoring straight out of the box without sourcing separate consumables. The GX-Force measures LEL combustibles, oxygen, carbon monoxide, and hydrogen sulfide through a 100-foot internal sample pump on a 30-hour battery.

Applications: Personal monitoring, Confined spaces, Refineries/petrochemical, Utilities, Oil and Gas, Water/wastewater, Fire services, Construction

Kit includes:

  • RKI GX-Force 4-gas monitor (LEL / O₂ / H₂S / CO) with Li-ion battery pack
  • One aluminum 34 L calibration gas cylinder (H₂S/CO/O₂/CH₄ mixture)
  • Demand flow regulator
  • Calibration tubing
  • Padded protective carrying case

Remember to calibrate every six months and regularly perform bump tests.

Note: calibration gas is not returnable. Please check your selection carefully before ordering.

Detection target gas Combustible gas (CH4) Oxygen (O2) Carbon monoxide (CO) Hydrogen sulfide (H2S)
Detection principle Catalytic combustion Electrochemical type Electrochemical type Electrochemical type
Detection range 0 – 100 % LEL 0.0 – 40.0 vol % 0 – 2,000 ppm 0.0 – 200.0 ppm
Resolution 1 % LEL 0.1 vol % 1 ppm 0.1 ppm
Alarm setpoints 1st alarm: 10 % LEL
2nd alarm: 25 % LEL
3rd alarm: 50 % LEL
OVER alarm: 100 % LEL
L alarm: 19.5 vol %
LL alarm: 18.0 vol %
H alarm: 23.5 vol %
OVER alarm: 40.0 vol %
1st alarm: 25 ppm
2nd alarm: 50 ppm
3rd alarm: 1200 ppm
TWA alarm: 25 ppm
STEL alarm: 200 ppm
OVER alarm: 2,000 ppm
1st alarm: 5.0 ppm
2nd alarm: 30.0 ppm
3rd alarm: 100.0 ppm
TWA alarm: 1.0 ppm
STEL alarm: 5.0 ppm
OVER alarm: 200.0 ppm
Response time (T90) Within 30 seconds Within 20 seconds Within 30 seconds Within 30 seconds

Specification Sheet:

Specification Sheet

Quick Reference Guide:

Quick Reference Guide

Manual:

Manual

Data Logger Manual:

Data Logger Manual

Part Number:
72-FA-A-A10-51

Related Searches
Calibration Gas, Confined Space Kits, Confined Space, Gas Detection, Multi-Gas Monitors, Portable Gas Monitors And Detectors, Rki Instruments

Frequently Asked Questions

What is the part number for this confined space kit?

This kit is part number 72-FA-A-A10-51. It includes the RKI GX-Force 4-gas monitor, a 34-liter aluminum calibration gas cylinder (H₂S/CO/O₂/CH₄), a demand flow regulator, calibration tubing, and a padded carrying case.

Why does this kit ship via UPS Ground only?

The 34-liter calibration gas cylinder is a hazardous material (compressed gas) subject to DOT regulations. Ground-only shipping applies regardless of your preferred shipping method, and the calibration gas is non-returnable. Please verify your cylinder gas mixture and quantity before placing the order.

How often should I calibrate the GX-Force?

RKI recommends a bump test (functional gas test) before each day of use and a full calibration at minimum every six months. The 34-liter cylinder included in this kit contains enough gas for multiple calibration cycles. When the cylinder is depleted, replacement calibration gas (part 81-0154RK-04) is available separately from PK Safety.

Does this kit include a wall charger for the GX-Force?

This confined space kit (72-FA-A-A10-51) includes the padded case, calibration gas, regulator, and tubing, but does not include a wall charger. The GX-Force with Case bundle (72-FA-A-A10-50) includes the charger. The 100–240 VAC AC adapter (part 49-0139) is available separately.

Can I use this calibration gas with other RKI monitors?

Yes. The 34 L H₂S/CO/O₂/CH₄ calibration gas mixture in this kit is also the standard four-gas mixture for the GX-3R, GX-3R Pro, GX-2009, and GX-2012. If you operate a mixed fleet, the same cylinder services multiple RKI instruments.

Specifications

  • Gas Type
    H2S/CO/CH4/O2
  • Height (in.)
    10
  • Length (in.)
    17
  • Width (in.)
    12

Reviews

Keep your team protected & compliant!

  • Expert guidance tailored to your specific needs
  • Access responsive customer support when you need it
  • Enjoy fast shipping directly to your location
  • Benefit from extensive industry knowledge—75+ years of experience
  • In-house gas detection calibration & repair services available
The RKI GX-Force Instrument Bundle by RKI Instruments comes in a black case and includes a CO detector kit, calibration gas with a silver gas cylinder, a black and red GX-Force Monitor, coiled hose, and various connectors. All components are neatly arranged in custom foam padding.
RKI Instruments

RKI Instruments GX-Force Confined Space Kit 72-FA-A-A10-51

$1,731.43

The RKI Instruments GX-Force Confined Space Kit (72-FA-A-A10-51) is a turnkey solution for OSHA-compliant confined space entry programs. Anchored by the GX-Force 4-gas monitor, this kit adds a pre-filled 34-liter calibration gas cylinder, demand flow regulator, tubing, and a padded carrying case. Teams can bump test, calibrate, and begin monitoring straight out of the box without sourcing separate consumables. The GX-Force measures LEL combustibles, oxygen, carbon monoxide, and hydrogen sulfide through a 100-foot internal sample pump on a 30-hour battery.

Applications: Personal monitoring, Confined spaces, Refineries/petrochemical, Utilities, Oil and Gas, Water/wastewater, Fire services, Construction

Kit includes:

Remember to calibrate every six months and regularly perform bump tests.

Note: calibration gas is not returnable. Please check your selection carefully before ordering.

Detection target gas Combustible gas (CH4) Oxygen (O2) Carbon monoxide (CO) Hydrogen sulfide (H2S)
Detection principle Catalytic combustion Electrochemical type Electrochemical type Electrochemical type
Detection range 0 – 100 % LEL 0.0 – 40.0 vol % 0 – 2,000 ppm 0.0 – 200.0 ppm
Resolution 1 % LEL 0.1 vol % 1 ppm 0.1 ppm
Alarm setpoints 1st alarm: 10 % LEL
2nd alarm: 25 % LEL
3rd alarm: 50 % LEL
OVER alarm: 100 % LEL
L alarm: 19.5 vol %
LL alarm: 18.0 vol %
H alarm: 23.5 vol %
OVER alarm: 40.0 vol %
1st alarm: 25 ppm
2nd alarm: 50 ppm
3rd alarm: 1200 ppm
TWA alarm: 25 ppm
STEL alarm: 200 ppm
OVER alarm: 2,000 ppm
1st alarm: 5.0 ppm
2nd alarm: 30.0 ppm
3rd alarm: 100.0 ppm
TWA alarm: 1.0 ppm
STEL alarm: 5.0 ppm
OVER alarm: 200.0 ppm
Response time (T90) Within 30 seconds Within 20 seconds Within 30 seconds Within 30 seconds

Specification Sheet:

Specification Sheet

Quick Reference Guide:

Quick Reference Guide

Manual:

Manual

Data Logger Manual:

Data Logger Manual

Part Number:
72-FA-A-A10-51

Related Searches
Calibration Gas, Confined Space Kits, Confined Space, Gas Detection, Multi-Gas Monitors, Portable Gas Monitors And Detectors, Rki Instruments

Frequently Asked Questions

What is the part number for this confined space kit?

This kit is part number 72-FA-A-A10-51. It includes the RKI GX-Force 4-gas monitor, a 34-liter aluminum calibration gas cylinder (H₂S/CO/O₂/CH₄), a demand flow regulator, calibration tubing, and a padded carrying case.

Why does this kit ship via UPS Ground only?

The 34-liter calibration gas cylinder is a hazardous material (compressed gas) subject to DOT regulations. Ground-only shipping applies regardless of your preferred shipping method, and the calibration gas is non-returnable. Please verify your cylinder gas mixture and quantity before placing the order.

How often should I calibrate the GX-Force?

RKI recommends a bump test (functional gas test) before each day of use and a full calibration at minimum every six months. The 34-liter cylinder included in this kit contains enough gas for multiple calibration cycles. When the cylinder is depleted, replacement calibration gas (part 81-0154RK-04) is available separately from PK Safety.

Does this kit include a wall charger for the GX-Force?

This confined space kit (72-FA-A-A10-51) includes the padded case, calibration gas, regulator, and tubing, but does not include a wall charger. The GX-Force with Case bundle (72-FA-A-A10-50) includes the charger. The 100–240 VAC AC adapter (part 49-0139) is available separately.

Can I use this calibration gas with other RKI monitors?

Yes. The 34 L H₂S/CO/O₂/CH₄ calibration gas mixture in this kit is also the standard four-gas mixture for the GX-3R, GX-3R Pro, GX-2009, and GX-2012. If you operate a mixed fleet, the same cylinder services multiple RKI instruments.

View product