Expert Guidance Monday-Friday, 6:30am-4pm PST. Call Now! Request a Quote Click Here!

SKU: RKI01-72-FA-A-A10-50

RKI GX-Force 4 Gas Monitor with Case 72-FA-A-A10-50

$1,335.83

Ships in 1 - 2 weeks

Description

The RKI GX-Force 4 Gas Monitor with Case delivers the complete out-of-the-box package for confined space and industrial gas monitoring. The GX-Force detects LEL combustibles, oxygen, carbon monoxide, and hydrogen sulfide simultaneously using a powerful 100-foot internal sample pump. This bundle adds a rechargeable 100–240 VAC charger, belt clip, USB-A to USB-C data cable, rubber sampling nozzle, 10-foot hose with wand, and a padded protective carrying case — everything a safety team needs to deploy immediately.

Applications: Personal monitoring, Confined spaces, Refineries/petrochemical, Utilities, Oil and Gas, Water/wastewater, Fire services, Construction

Bundle includes:

  • RKI GX-Force 4-gas monitor (LEL / O₂ / H₂S / CO) with Li-ion battery pack
  • 100–240 VAC wall charger
  • Belt clip
  • USB-A to USB-C data download cable
  • Rubber sampling nozzle
  • 10-foot sampling hose with wand
  • Padded protective carrying case

Remember to calibrate every six months and regularly perform bump tests.

Note: calibration gas is not returnable. Please check your selection carefully before ordering.

Detection target gas Combustible gas (CH4) Oxygen (O2) Carbon monoxide (CO) Hydrogen sulfide (H2S)
Detection principle Catalytic combustion Electrochemical type Electrochemical type Electrochemical type
Detection range 0 – 100 % LEL 0.0 – 40.0 vol % 0 – 2,000 ppm 0.0 – 200.0 ppm
Resolution 1 % LEL 0.1 vol % 1 ppm 0.1 ppm
Alarm setpoints 1st alarm: 10 % LEL
2nd alarm: 25 % LEL
3rd alarm: 50 % LEL
OVER alarm: 100 % LEL
L alarm: 19.5 vol %
LL alarm: 18.0 vol %
H alarm: 23.5 vol %
OVER alarm: 40.0 vol %
1st alarm: 25 ppm
2nd alarm: 50 ppm
3rd alarm: 1200 ppm
TWA alarm: 25 ppm
STEL alarm: 200 ppm
OVER alarm: 2,000 ppm
1st alarm: 5.0 ppm
2nd alarm: 30.0 ppm
3rd alarm: 100.0 ppm
TWA alarm: 1.0 ppm
STEL alarm: 5.0 ppm
OVER alarm: 200.0 ppm
Response time (T90) Within 30 seconds Within 20 seconds Within 30 seconds Within 30 seconds

Specification Sheet:

Specification Sheet

Quick Reference Guide:

Quick Reference Guide

Manual:

Manual

Data Logger Manual:

Data Logger Manual

Part Number:
72-FA-A-A10-50

Frequently Asked Questions

What is included in the GX-Force with Case bundle?

This bundle (part 72-FA-A-A10-50) includes the RKI GX-Force 4-gas monitor with Li-ion battery, a 100–240 VAC wall charger, belt clip, USB-A to USB-C data cable, rubber sampling nozzle, 10-foot hose with wand, and a padded protective carrying case. It is a complete ready-to-use kit requiring no additional accessories to begin monitoring.

How does this bundle differ from the standalone GX-Force monitor?

The standalone GX-Force (72-FA-A-A10) ships with the monitor and battery only. This bundle adds the padded carrying case, wall charger, belt clip, USB data cable, rubber nozzle, and 10-foot sampling hose — making it the preferred choice for teams that want a complete, protected field kit from day one.

Is calibration gas included in this bundle?

No — this bundle does not include calibration gas. For a kit that adds calibration gas, a demand flow regulator, and tubing, see the GX-Force Confined Space Kit (72-FA-A-A10-51). RKI recommends bump-testing the instrument before each day of use and full calibration at least every six months with a 4-gas mixture such as the RKI 81-0154RK-04.

Can I use the included charger outside the United States?

Yes. The 100–240 VAC wall charger is universal — it works with standard AC outlets in the US, Canada, and internationally (with an appropriate plug adapter). For vehicle charging, the optional 12–24 VDC DC adapter (part 49-2022) is sold separately.

What replacement sensors fit the GX-Force in this bundle?

The GX-Force uses field-replaceable sensors: ESR-A1DP-COHS (dual CO/H₂S electrochemical), ESR-X13P-OXY (O₂ galvanic), and NCR-6309 (LEL catalytic bead). All three are available individually from PK Safety. Replace sensors at or before the end of their rated service life (typically 2–3 years for electrochemical cells).

Read more

The RKI GX-Force 4 Gas Monitor with Case delivers the complete out-of-the-box package for confined space and industrial gas monitoring. The GX-Force detects LEL combustibles, oxygen, carbon monoxide, and hydrogen sulfide simultaneously using a powerful 100-foot internal sample pump. This bundle adds a rechargeable 100–240 VAC charger, belt clip, USB-A to USB-C data cable, rubber sampling nozzle, 10-foot hose with wand, and a padded protective carrying case — everything a safety team needs to deploy immediately.

Applications: Personal monitoring, Confined spaces, Refineries/petrochemical, Utilities, Oil and Gas, Water/wastewater, Fire services, Construction

Bundle includes:

  • RKI GX-Force 4-gas monitor (LEL / O₂ / H₂S / CO) with Li-ion battery pack
  • 100–240 VAC wall charger
  • Belt clip
  • USB-A to USB-C data download cable
  • Rubber sampling nozzle
  • 10-foot sampling hose with wand
  • Padded protective carrying case

Remember to calibrate every six months and regularly perform bump tests.

Note: calibration gas is not returnable. Please check your selection carefully before ordering.

Detection target gas Combustible gas (CH4) Oxygen (O2) Carbon monoxide (CO) Hydrogen sulfide (H2S)
Detection principle Catalytic combustion Electrochemical type Electrochemical type Electrochemical type
Detection range 0 – 100 % LEL 0.0 – 40.0 vol % 0 – 2,000 ppm 0.0 – 200.0 ppm
Resolution 1 % LEL 0.1 vol % 1 ppm 0.1 ppm
Alarm setpoints 1st alarm: 10 % LEL
2nd alarm: 25 % LEL
3rd alarm: 50 % LEL
OVER alarm: 100 % LEL
L alarm: 19.5 vol %
LL alarm: 18.0 vol %
H alarm: 23.5 vol %
OVER alarm: 40.0 vol %
1st alarm: 25 ppm
2nd alarm: 50 ppm
3rd alarm: 1200 ppm
TWA alarm: 25 ppm
STEL alarm: 200 ppm
OVER alarm: 2,000 ppm
1st alarm: 5.0 ppm
2nd alarm: 30.0 ppm
3rd alarm: 100.0 ppm
TWA alarm: 1.0 ppm
STEL alarm: 5.0 ppm
OVER alarm: 200.0 ppm
Response time (T90) Within 30 seconds Within 20 seconds Within 30 seconds Within 30 seconds

Specification Sheet:

Specification Sheet

Quick Reference Guide:

Quick Reference Guide

Manual:

Manual

Data Logger Manual:

Data Logger Manual

Part Number:
72-FA-A-A10-50

Frequently Asked Questions

What is included in the GX-Force with Case bundle?

This bundle (part 72-FA-A-A10-50) includes the RKI GX-Force 4-gas monitor with Li-ion battery, a 100–240 VAC wall charger, belt clip, USB-A to USB-C data cable, rubber sampling nozzle, 10-foot hose with wand, and a padded protective carrying case. It is a complete ready-to-use kit requiring no additional accessories to begin monitoring.

How does this bundle differ from the standalone GX-Force monitor?

The standalone GX-Force (72-FA-A-A10) ships with the monitor and battery only. This bundle adds the padded carrying case, wall charger, belt clip, USB data cable, rubber nozzle, and 10-foot sampling hose — making it the preferred choice for teams that want a complete, protected field kit from day one.

Is calibration gas included in this bundle?

No — this bundle does not include calibration gas. For a kit that adds calibration gas, a demand flow regulator, and tubing, see the GX-Force Confined Space Kit (72-FA-A-A10-51). RKI recommends bump-testing the instrument before each day of use and full calibration at least every six months with a 4-gas mixture such as the RKI 81-0154RK-04.

Can I use the included charger outside the United States?

Yes. The 100–240 VAC wall charger is universal — it works with standard AC outlets in the US, Canada, and internationally (with an appropriate plug adapter). For vehicle charging, the optional 12–24 VDC DC adapter (part 49-2022) is sold separately.

What replacement sensors fit the GX-Force in this bundle?

The GX-Force uses field-replaceable sensors: ESR-A1DP-COHS (dual CO/H₂S electrochemical), ESR-X13P-OXY (O₂ galvanic), and NCR-6309 (LEL catalytic bead). All three are available individually from PK Safety. Replace sensors at or before the end of their rated service life (typically 2–3 years for electrochemical cells).

Specifications

  • MPN
    72-FA-A-A10-50
  • Gas Type
    H2S/CO/CH4/O2
  • Product Weight (lbs.)
    19
  • Country of Origin
    JP

Reviews

Keep your team protected & compliant!

  • Expert guidance tailored to your specific needs
  • Access responsive customer support when you need it
  • Enjoy fast shipping directly to your location
  • Benefit from extensive industry knowledge—75+ years of experience
  • In-house gas detection calibration & repair services available
The RKI Instruments GX-Force 4 Gas Monitor with Case (72-FA-A-A10-50) includes a hard case, foam inserts, charger, USB cable, coiled tubing, probe, and adapter—organized for multi-gas detection in confined spaces.
RKI Instruments

RKI GX-Force 4 Gas Monitor with Case 72-FA-A-A10-50

$1,335.83

The RKI GX-Force 4 Gas Monitor with Case delivers the complete out-of-the-box package for confined space and industrial gas monitoring. The GX-Force detects LEL combustibles, oxygen, carbon monoxide, and hydrogen sulfide simultaneously using a powerful 100-foot internal sample pump. This bundle adds a rechargeable 100–240 VAC charger, belt clip, USB-A to USB-C data cable, rubber sampling nozzle, 10-foot hose with wand, and a padded protective carrying case — everything a safety team needs to deploy immediately.

Applications: Personal monitoring, Confined spaces, Refineries/petrochemical, Utilities, Oil and Gas, Water/wastewater, Fire services, Construction

Bundle includes:

Remember to calibrate every six months and regularly perform bump tests.

Note: calibration gas is not returnable. Please check your selection carefully before ordering.

Detection target gas Combustible gas (CH4) Oxygen (O2) Carbon monoxide (CO) Hydrogen sulfide (H2S)
Detection principle Catalytic combustion Electrochemical type Electrochemical type Electrochemical type
Detection range 0 – 100 % LEL 0.0 – 40.0 vol % 0 – 2,000 ppm 0.0 – 200.0 ppm
Resolution 1 % LEL 0.1 vol % 1 ppm 0.1 ppm
Alarm setpoints 1st alarm: 10 % LEL
2nd alarm: 25 % LEL
3rd alarm: 50 % LEL
OVER alarm: 100 % LEL
L alarm: 19.5 vol %
LL alarm: 18.0 vol %
H alarm: 23.5 vol %
OVER alarm: 40.0 vol %
1st alarm: 25 ppm
2nd alarm: 50 ppm
3rd alarm: 1200 ppm
TWA alarm: 25 ppm
STEL alarm: 200 ppm
OVER alarm: 2,000 ppm
1st alarm: 5.0 ppm
2nd alarm: 30.0 ppm
3rd alarm: 100.0 ppm
TWA alarm: 1.0 ppm
STEL alarm: 5.0 ppm
OVER alarm: 200.0 ppm
Response time (T90) Within 30 seconds Within 20 seconds Within 30 seconds Within 30 seconds

Specification Sheet:

Specification Sheet

Quick Reference Guide:

Quick Reference Guide

Manual:

Manual

Data Logger Manual:

Data Logger Manual

Part Number:
72-FA-A-A10-50

Frequently Asked Questions

What is included in the GX-Force with Case bundle?

This bundle (part 72-FA-A-A10-50) includes the RKI GX-Force 4-gas monitor with Li-ion battery, a 100–240 VAC wall charger, belt clip, USB-A to USB-C data cable, rubber sampling nozzle, 10-foot hose with wand, and a padded protective carrying case. It is a complete ready-to-use kit requiring no additional accessories to begin monitoring.

How does this bundle differ from the standalone GX-Force monitor?

The standalone GX-Force (72-FA-A-A10) ships with the monitor and battery only. This bundle adds the padded carrying case, wall charger, belt clip, USB data cable, rubber nozzle, and 10-foot sampling hose — making it the preferred choice for teams that want a complete, protected field kit from day one.

Is calibration gas included in this bundle?

No — this bundle does not include calibration gas. For a kit that adds calibration gas, a demand flow regulator, and tubing, see the GX-Force Confined Space Kit (72-FA-A-A10-51). RKI recommends bump-testing the instrument before each day of use and full calibration at least every six months with a 4-gas mixture such as the RKI 81-0154RK-04.

Can I use the included charger outside the United States?

Yes. The 100–240 VAC wall charger is universal — it works with standard AC outlets in the US, Canada, and internationally (with an appropriate plug adapter). For vehicle charging, the optional 12–24 VDC DC adapter (part 49-2022) is sold separately.

What replacement sensors fit the GX-Force in this bundle?

The GX-Force uses field-replaceable sensors: ESR-A1DP-COHS (dual CO/H₂S electrochemical), ESR-X13P-OXY (O₂ galvanic), and NCR-6309 (LEL catalytic bead). All three are available individually from PK Safety. Replace sensors at or before the end of their rated service life (typically 2–3 years for electrochemical cells).

View product