SKU: RKI01-65-2640XL

RKI Explosion Proof M2A-XL Transmitter w/J-Box, UL 65-264_XL

$1,603.85

Ships in 6 - 8 weeks

Description

The RKI Explosion Proof UL-listed M2A-XL Transmitter with junction box shares the same electronics and mounting pattern as the original M2A but provides a slightly larger enclosure with additional internal wiring room. Available in LEL general-purpose catalytic, H2-specific LEL, IR Methane (CH4), and IR Hydrocarbon configurations.

Please call Customer Service at 800.829.9580 if you have questions in choosing the correct product.

The M2A-XL operates as a stand-alone monitor or connects to any controller, PLC, or DCS. Compatible with: Beacon 110, Beacon 200, Beacon 410, or Beacon 800.

Applications: Petrochemical plants, Refineries, Water & wastewater treatment plants, Pulp & paper mills, Manufacturing facilities, Automotive, Semiconductor plants, Chemical plants

Key Features:

  • Operates with or without a controller
  • OLED cold-temperature display with direct digital readout
  • LEL catalytic, H2-specific LEL, IR CH4, and IR HC configurations
  • 4-20 mA & digital Modbus outputs standard
  • 2 fully programmable alarm relays & fail relay
  • Non-intrusive magnetic-wand calibration
  • UL-listed explosion-proof construction
  • Patented water-repellent sensor cover
  • Long-life sensors: 2+ yr catalytic; 5+ yr IR

Specifications by Configuration:

LEL 0-100% (catalytic): Accuracy +/-5% of reading or 2% LEL; Response time 35 s or less; Sensor life 2-3 yr. Part: 65-2640XL

H2-Specific LEL: Range 0-100% LEL (H2); Accuracy +/-5% of reading or 2% LEL; Sensor life 3-5 yr. Part: 65-2641XL

IR CH4 LEL 0-100%: Accuracy +/-5% reading or +/-2% full scale; Response 30 s; Sensor life 5+ yr. Part: 65-2649XL-CH4

IR CH4 0-100% Vol: Accuracy +/-5% reading or +/-2% full scale; Response 30 s; Sensor life 5+ yr. Part: 65-2658XL-CH4

IR Hydrocarbons LEL 0-100%: Accuracy +/-5% reading or +/-2% full scale; Response 30 s or less; Sensor life 5+ yr. Part: 65-2649XL-HC

Specification Sheet:

Specification Sheet

Manual:

Manual

Part Numbers:
65-2640XL - LEL 0-100% (catalytic)
65-2641XL - H2-specific LEL 0-100%
65-2649XL-CH4 - IR CH4 LEL 0-100%
65-2658XL-CH4 - IR CH4 0-100% Vol
65-2649XL-HC - IR Hydrocarbons LEL 0-100%

Frequently Asked Questions

What gases can the RKI M2A-XL Explosion Proof Transmitter detect?

The M2A-XL is available in four sensing technologies: LEL general-purpose catalytic (65-2640XL), H2-specific LEL (65-2641XL), IR Methane in both LEL and 100% volume ranges (65-2649XL-CH4 and 65-2658XL-CH4), and IR Hydrocarbons LEL (65-2649XL-HC). Select the configuration matched to your facility's primary combustible-gas hazard.

Can the M2A-XL operate without a controller?

Yes. The M2A-XL includes an OLED display, two fully programmable alarm relays, and a fail relay, enabling stand-alone operation with local alarming. It also integrates with Beacon 110, Beacon 200, Beacon 410, or Beacon 800 controllers or virtually any PLC or DCS via standard 4-20 mA and Modbus outputs.

How long do M2A-XL sensors last and how is calibration performed?

Catalytic LEL sensors last 2-3 years; H2-specific LEL sensors 3-5 years; IR sensors 5+ years. Calibration is non-intrusive via the built-in magnetic wand interface, eliminating the need to open the explosion-proof enclosure during routine maintenance.

What certifications does the M2A-XL carry?

The M2A-XL carries UL explosion-proof certification and features a patented water-repellent sensor cover. It is designed for petrochemical plants, refineries, water and wastewater treatment facilities, semiconductor plants, and other demanding industrial environments.

Does PK Safety service the RKI M2A-XL?

Yes. As an RKI Factory Authorized Service Center, PK Safety provides calibration, repair, and technical support for the M2A-XL. Call 800.829.9580 for parts, service scheduling, or application guidance.

Related Searches
Fixed Gas Detectors, Gas Detection

Read more

The RKI Explosion Proof UL-listed M2A-XL Transmitter with junction box shares the same electronics and mounting pattern as the original M2A but provides a slightly larger enclosure with additional internal wiring room. Available in LEL general-purpose catalytic, H2-specific LEL, IR Methane (CH4), and IR Hydrocarbon configurations.

Please call Customer Service at 800.829.9580 if you have questions in choosing the correct product.

The M2A-XL operates as a stand-alone monitor or connects to any controller, PLC, or DCS. Compatible with: Beacon 110, Beacon 200, Beacon 410, or Beacon 800.

Applications: Petrochemical plants, Refineries, Water & wastewater treatment plants, Pulp & paper mills, Manufacturing facilities, Automotive, Semiconductor plants, Chemical plants

Key Features:

  • Operates with or without a controller
  • OLED cold-temperature display with direct digital readout
  • LEL catalytic, H2-specific LEL, IR CH4, and IR HC configurations
  • 4-20 mA & digital Modbus outputs standard
  • 2 fully programmable alarm relays & fail relay
  • Non-intrusive magnetic-wand calibration
  • UL-listed explosion-proof construction
  • Patented water-repellent sensor cover
  • Long-life sensors: 2+ yr catalytic; 5+ yr IR

Specifications by Configuration:

LEL 0-100% (catalytic): Accuracy +/-5% of reading or 2% LEL; Response time 35 s or less; Sensor life 2-3 yr. Part: 65-2640XL

H2-Specific LEL: Range 0-100% LEL (H2); Accuracy +/-5% of reading or 2% LEL; Sensor life 3-5 yr. Part: 65-2641XL

IR CH4 LEL 0-100%: Accuracy +/-5% reading or +/-2% full scale; Response 30 s; Sensor life 5+ yr. Part: 65-2649XL-CH4

IR CH4 0-100% Vol: Accuracy +/-5% reading or +/-2% full scale; Response 30 s; Sensor life 5+ yr. Part: 65-2658XL-CH4

IR Hydrocarbons LEL 0-100%: Accuracy +/-5% reading or +/-2% full scale; Response 30 s or less; Sensor life 5+ yr. Part: 65-2649XL-HC

Specification Sheet:

Specification Sheet

Manual:

Manual

Part Numbers:
65-2640XL - LEL 0-100% (catalytic)
65-2641XL - H2-specific LEL 0-100%
65-2649XL-CH4 - IR CH4 LEL 0-100%
65-2658XL-CH4 - IR CH4 0-100% Vol
65-2649XL-HC - IR Hydrocarbons LEL 0-100%

Frequently Asked Questions

What gases can the RKI M2A-XL Explosion Proof Transmitter detect?

The M2A-XL is available in four sensing technologies: LEL general-purpose catalytic (65-2640XL), H2-specific LEL (65-2641XL), IR Methane in both LEL and 100% volume ranges (65-2649XL-CH4 and 65-2658XL-CH4), and IR Hydrocarbons LEL (65-2649XL-HC). Select the configuration matched to your facility's primary combustible-gas hazard.

Can the M2A-XL operate without a controller?

Yes. The M2A-XL includes an OLED display, two fully programmable alarm relays, and a fail relay, enabling stand-alone operation with local alarming. It also integrates with Beacon 110, Beacon 200, Beacon 410, or Beacon 800 controllers or virtually any PLC or DCS via standard 4-20 mA and Modbus outputs.

How long do M2A-XL sensors last and how is calibration performed?

Catalytic LEL sensors last 2-3 years; H2-specific LEL sensors 3-5 years; IR sensors 5+ years. Calibration is non-intrusive via the built-in magnetic wand interface, eliminating the need to open the explosion-proof enclosure during routine maintenance.

What certifications does the M2A-XL carry?

The M2A-XL carries UL explosion-proof certification and features a patented water-repellent sensor cover. It is designed for petrochemical plants, refineries, water and wastewater treatment facilities, semiconductor plants, and other demanding industrial environments.

Does PK Safety service the RKI M2A-XL?

Yes. As an RKI Factory Authorized Service Center, PK Safety provides calibration, repair, and technical support for the M2A-XL. Call 800.829.9580 for parts, service scheduling, or application guidance.

Related Searches
Fixed Gas Detectors, Gas Detection

Specifications

  • Product Weight (lbs.)
    0.871
  • Height (in.)
    8
  • Length (in.)
    13.5
  • Width (in.)
    10

Reviews

Keep your team protected & compliant!

  • Expert guidance tailored to your specific needs
  • Access responsive customer support when you need it
  • Enjoy fast shipping directly to your location
  • Benefit from extensive industry knowledge—75+ years of experience
  • In-house gas detection calibration & repair services available
A gray RKI Explosion Proof M2A-XL Transmitter with an exposed circuit board and a digital display showing "RKI Instruments" and "M2A-XLF TRANSMITTER," featuring a cylindrical LEL sensor on the right.
RKI Instruments

RKI Explosion Proof M2A-XL Transmitter w/J-Box, UL 65-264_XL

From $1,603.85

The RKI Explosion Proof UL-listed M2A-XL Transmitter with junction box shares the same electronics and mounting pattern as the original M2A but provides a slightly larger enclosure with additional internal wiring room. Available in LEL general-purpose catalytic, H2-specific LEL, IR Methane (CH4), and IR Hydrocarbon configurations.

Please call Customer Service at 800.829.9580 if you have questions in choosing the correct product.

The M2A-XL operates as a stand-alone monitor or connects to any controller, PLC, or DCS. Compatible with: Beacon 110, Beacon 200, Beacon 410, or Beacon 800.

Applications: Petrochemical plants, Refineries, Water & wastewater treatment plants, Pulp & paper mills, Manufacturing facilities, Automotive, Semiconductor plants, Chemical plants

Key Features:

Specifications by Configuration:

LEL 0-100% (catalytic): Accuracy +/-5% of reading or 2% LEL; Response time 35 s or less; Sensor life 2-3 yr. Part: 65-2640XL

H2-Specific LEL: Range 0-100% LEL (H2); Accuracy +/-5% of reading or 2% LEL; Sensor life 3-5 yr. Part: 65-2641XL

IR CH4 LEL 0-100%: Accuracy +/-5% reading or +/-2% full scale; Response 30 s; Sensor life 5+ yr. Part: 65-2649XL-CH4

IR CH4 0-100% Vol: Accuracy +/-5% reading or +/-2% full scale; Response 30 s; Sensor life 5+ yr. Part: 65-2658XL-CH4

IR Hydrocarbons LEL 0-100%: Accuracy +/-5% reading or +/-2% full scale; Response 30 s or less; Sensor life 5+ yr. Part: 65-2649XL-HC

Specification Sheet:

Specification Sheet

Manual:

Manual

Part Numbers:
65-2640XL - LEL 0-100% (catalytic)
65-2641XL - H2-specific LEL 0-100%
65-2649XL-CH4 - IR CH4 LEL 0-100%
65-2658XL-CH4 - IR CH4 0-100% Vol
65-2649XL-HC - IR Hydrocarbons LEL 0-100%

Frequently Asked Questions

What gases can the RKI M2A-XL Explosion Proof Transmitter detect?

The M2A-XL is available in four sensing technologies: LEL general-purpose catalytic (65-2640XL), H2-specific LEL (65-2641XL), IR Methane in both LEL and 100% volume ranges (65-2649XL-CH4 and 65-2658XL-CH4), and IR Hydrocarbons LEL (65-2649XL-HC). Select the configuration matched to your facility's primary combustible-gas hazard.

Can the M2A-XL operate without a controller?

Yes. The M2A-XL includes an OLED display, two fully programmable alarm relays, and a fail relay, enabling stand-alone operation with local alarming. It also integrates with Beacon 110, Beacon 200, Beacon 410, or Beacon 800 controllers or virtually any PLC or DCS via standard 4-20 mA and Modbus outputs.

How long do M2A-XL sensors last and how is calibration performed?

Catalytic LEL sensors last 2-3 years; H2-specific LEL sensors 3-5 years; IR sensors 5+ years. Calibration is non-intrusive via the built-in magnetic wand interface, eliminating the need to open the explosion-proof enclosure during routine maintenance.

What certifications does the M2A-XL carry?

The M2A-XL carries UL explosion-proof certification and features a patented water-repellent sensor cover. It is designed for petrochemical plants, refineries, water and wastewater treatment facilities, semiconductor plants, and other demanding industrial environments.

Does PK Safety service the RKI M2A-XL?

Yes. As an RKI Factory Authorized Service Center, PK Safety provides calibration, repair, and technical support for the M2A-XL. Call 800.829.9580 for parts, service scheduling, or application guidance.

Related Searches
Fixed Gas Detectors, Gas Detection

Gas Type

  • LEL 0-100% (catalytic)
  • H2 Specific LEL
  • CH4 - 0-100% Vol.
  • IR CH4 LEL 0-100%
  • IR Hydrocarbons LEL 0-100%