Description

The RKI Direct Connect H2-Specific LEL Sensor provides targeted hydrogen detection for applications where hydrogen-specific discrimination is required. Unlike general-purpose LEL sensors, this sensor uses a catalytic element selected for hydrogen, delivering a fast 20-second response and a long 3–5 year service life. Explosion-proof with flame arrestors for use in Class I, Groups B, C, and D hazardous areas.

Compatible with Beacon 110, Beacon 200, and Beacon 410 controllers. Also see the LEL, CH4, and CO2 sensor and the O2, H2S, CO sensor.

Key Features:

  • Electrochemical plug-in sensor — no tools required for replacement
  • Hydrogen-specific catalytic detection
  • Fast 20-second response time
  • Compatible with Beacon 110, Beacon 200, and Beacon 410
  • Indoor/outdoor rated
  • Explosion-proof construction with flame arrestors
  • Long sensor life (3–5 years typical)

LEL, H2 Specific

  • Measuring Range: 0–100% LEL
  • Lower Detectable Limit (LDL): 2% of full scale
  • Response Time: 20 seconds
  • Life Expectancy: 3–5 years with normal service
  • Part Numbers:
    NC-6205-01 — Sensor only
    61-1001RK — With J-Box
PK Safety services RKI Instruments fixed gas detection systems in-house — call 800.829.9580 for product guidance or service scheduling.

Related Searches
Fixed Gas Detectors, Gas Detection, RKI Instruments, Safety Equipment, Sensors

Frequently Asked Questions

Why use an H2-specific LEL sensor instead of a general LEL sensor?

General-purpose LEL sensors are calibrated for one reference gas (often isobutylene or methane) and can read lower or higher for hydrogen due to its different thermal conductivity. An H2-specific sensor is optimized for hydrogen response, providing more accurate readings in hydrogen-only applications such as fuel cell facilities, battery charging rooms, and hydrogen storage areas.

What applications require H2-specific LEL detection?

H2-specific detection is commonly required in lead-acid battery charging areas, hydrogen fuel cell installations, electrolysis facilities, hydrogen storage and fueling stations, and any process that generates or uses hydrogen as a feedstock or byproduct.

What is the LEL for hydrogen, and what does OSHA require?

Hydrogen's lower explosive limit (LEL) is 4% by volume in air. Under 29 CFR 1910.1000 and NFPA 2, fixed detection systems with alarms at 10% LEL (action level) and 25% LEL (evacuation level) are commonly specified. Consult your industrial hygienist or fire protection engineer for your specific alarm set-point strategy.

How fast does this sensor respond to hydrogen?

The H2-specific Direct Connect sensor has a 20-second response time — faster than the 30-second response of the general-purpose LEL sensor — which is important in rapidly evolving hydrogen release scenarios.

How does PK Safety support RKI fixed H2 detection systems?

PK Safety services RKI Instruments fixed detection equipment in-house with factory-trained technicians. We can assist with sensor replacement, system calibration, and controller setup. Call 800.829.9580 for service or application support.

Read more

The RKI Direct Connect H2-Specific LEL Sensor provides targeted hydrogen detection for applications where hydrogen-specific discrimination is required. Unlike general-purpose LEL sensors, this sensor uses a catalytic element selected for hydrogen, delivering a fast 20-second response and a long 3–5 year service life. Explosion-proof with flame arrestors for use in Class I, Groups B, C, and D hazardous areas.

Compatible with Beacon 110, Beacon 200, and Beacon 410 controllers. Also see the LEL, CH4, and CO2 sensor and the O2, H2S, CO sensor.

Key Features:

  • Electrochemical plug-in sensor — no tools required for replacement
  • Hydrogen-specific catalytic detection
  • Fast 20-second response time
  • Compatible with Beacon 110, Beacon 200, and Beacon 410
  • Indoor/outdoor rated
  • Explosion-proof construction with flame arrestors
  • Long sensor life (3–5 years typical)

LEL, H2 Specific

  • Measuring Range: 0–100% LEL
  • Lower Detectable Limit (LDL): 2% of full scale
  • Response Time: 20 seconds
  • Life Expectancy: 3–5 years with normal service
  • Part Numbers:
    NC-6205-01 — Sensor only
    61-1001RK — With J-Box
PK Safety services RKI Instruments fixed gas detection systems in-house — call 800.829.9580 for product guidance or service scheduling.

Related Searches
Fixed Gas Detectors, Gas Detection, RKI Instruments, Safety Equipment, Sensors

Frequently Asked Questions

Why use an H2-specific LEL sensor instead of a general LEL sensor?

General-purpose LEL sensors are calibrated for one reference gas (often isobutylene or methane) and can read lower or higher for hydrogen due to its different thermal conductivity. An H2-specific sensor is optimized for hydrogen response, providing more accurate readings in hydrogen-only applications such as fuel cell facilities, battery charging rooms, and hydrogen storage areas.

What applications require H2-specific LEL detection?

H2-specific detection is commonly required in lead-acid battery charging areas, hydrogen fuel cell installations, electrolysis facilities, hydrogen storage and fueling stations, and any process that generates or uses hydrogen as a feedstock or byproduct.

What is the LEL for hydrogen, and what does OSHA require?

Hydrogen's lower explosive limit (LEL) is 4% by volume in air. Under 29 CFR 1910.1000 and NFPA 2, fixed detection systems with alarms at 10% LEL (action level) and 25% LEL (evacuation level) are commonly specified. Consult your industrial hygienist or fire protection engineer for your specific alarm set-point strategy.

How fast does this sensor respond to hydrogen?

The H2-specific Direct Connect sensor has a 20-second response time — faster than the 30-second response of the general-purpose LEL sensor — which is important in rapidly evolving hydrogen release scenarios.

How does PK Safety support RKI fixed H2 detection systems?

PK Safety services RKI Instruments fixed detection equipment in-house with factory-trained technicians. We can assist with sensor replacement, system calibration, and controller setup. Call 800.829.9580 for service or application support.

Specifications

  • Gas Type
    LEL, H2 Specific
  • Product Weight (lbs.)
    4.0
  • Height (in.)
    1
  • Length (in.)
    12
  • Width (in.)
    8.5
  • Country of Origin
    JP

Reviews

Keep your team protected & compliant!

  • Expert guidance tailored to your specific needs
  • Access responsive customer support when you need it
  • Enjoy fast shipping directly to your location
  • Benefit from extensive industry knowledge—75+ years of experience
  • In-house gas detection calibration & repair services available
The RKI Direct Connect Gas Sensor LEL, H2 Specific features two industrial metal enclosures prominently branded with "RKI Instruments" on top. These enclosures have cylindrical bases and connectors for securely attaching equipment. Their explosion-proof design ensures safety when used in environments containing toxic gases. Additionally, they exhibit a rugged, metallic finish.
RKI Instruments

RKI Direct Connect Gas Sensor LEL, H2 Specific

From $450.00

The RKI Direct Connect H2-Specific LEL Sensor provides targeted hydrogen detection for applications where hydrogen-specific discrimination is required. Unlike general-purpose LEL sensors, this sensor uses a catalytic element selected for hydrogen, delivering a fast 20-second response and a long 3–5 year service life. Explosion-proof with flame arrestors for use in Class I, Groups B, C, and D hazardous areas.

Compatible with Beacon 110, Beacon 200, and Beacon 410 controllers. Also see the LEL, CH4, and CO2 sensor and the O2, H2S, CO sensor.

Key Features:

LEL, H2 Specific

PK Safety services RKI Instruments fixed gas detection systems in-house — call 800.829.9580 for product guidance or service scheduling.

Related Searches
Fixed Gas Detectors, Gas Detection, RKI Instruments, Safety Equipment, Sensors

Frequently Asked Questions

Why use an H2-specific LEL sensor instead of a general LEL sensor?

General-purpose LEL sensors are calibrated for one reference gas (often isobutylene or methane) and can read lower or higher for hydrogen due to its different thermal conductivity. An H2-specific sensor is optimized for hydrogen response, providing more accurate readings in hydrogen-only applications such as fuel cell facilities, battery charging rooms, and hydrogen storage areas.

What applications require H2-specific LEL detection?

H2-specific detection is commonly required in lead-acid battery charging areas, hydrogen fuel cell installations, electrolysis facilities, hydrogen storage and fueling stations, and any process that generates or uses hydrogen as a feedstock or byproduct.

What is the LEL for hydrogen, and what does OSHA require?

Hydrogen's lower explosive limit (LEL) is 4% by volume in air. Under 29 CFR 1910.1000 and NFPA 2, fixed detection systems with alarms at 10% LEL (action level) and 25% LEL (evacuation level) are commonly specified. Consult your industrial hygienist or fire protection engineer for your specific alarm set-point strategy.

How fast does this sensor respond to hydrogen?

The H2-specific Direct Connect sensor has a 20-second response time — faster than the 30-second response of the general-purpose LEL sensor — which is important in rapidly evolving hydrogen release scenarios.

How does PK Safety support RKI fixed H2 detection systems?

PK Safety services RKI Instruments fixed detection equipment in-house with factory-trained technicians. We can assist with sensor replacement, system calibration, and controller setup. Call 800.829.9580 for service or application support.

Configuration

  • Add J-Box
  • Sensor Only
View product