ISG Fixed Flow Regulator (0.25 LPM) w/Tubing
We proudly serve diverse industries including construction, oil and gas, confined space operations, manufacturing, and more. Contact our California-based safety experts or give them a call for personalized guidance on your safety needs.
Description
Description
The ISG Fixed Flow Regulator delivers a constant 0.25 LPM of non-reactive calibration gas to diffusion instruments — the kind of 4-gas detector or single-gas clip that passively absorbs gas without an internal pump. It's the straightforward choice for routine bump tests and span calibrations on diffusion-only hardware.
Key Specifications:
- Flow: 0.25 LPM (fixed)
- Valve inlet: C-10 (fits ISG 20L, 34L, 58L, 103L, FX75, FX120 cylinders)
- Maximum cylinder pressure: 1,200 PSIG
- Material: Nickel-plated brass
- Includes: 1 ft of tubing
- Gas types: Non-reactive only
- Made in the USA
Part Number:
R-025
Frequently Asked Questions
Why 0.25 LPM specifically?
0.25 LPM is a common target flow for diffusion instrument bump tests because it lightly over-pressurizes the sensor inlet without flooding the sensor or wasting cal gas. Manufacturer manuals typically specify a flow range; 0.25 LPM sits comfortably in the standard window for most 4-gas and single-gas diffusion detectors.
When is fixed flow the wrong choice?
Any time the instrument has an internal sampling pump (bellows or diaphragm) that pulls gas actively. A fixed-flow regulator fighting an internal pump produces inconsistent readings and failed calibrations. For pumped instruments and docking stations, use a demand flow regulator instead.
What gases is this rated for?
Non-reactive calibration mixes only — standard 4-gas blends, methane, CO, zero air. Reactive gases (H2S above trace, Cl2, NH3, SO2) require a stainless-steel wetted-path regulator; the nickel-plated brass construction here isn't suitable for sustained reactive-gas service.
Do I need the tubing accessory separately?
No — 1 ft of tubing is included with the regulator and is enough to reach a sensor port on most diffusion instruments. If your bump station or sensor cup needs a longer run, standard 1/8" Tygon tubing is interchangeable.
Related Searches:
Calibration Gas, Gas Detection, Gas Detector Accessories, Intermountain Specialty Gases, Regulators
Specifications
Specifications
-
MPN
-
Product Weight (lbs.)
-
Country of Origin
Reviews
Reviews
Keep your team protected & compliant!
- Expert guidance tailored to your specific needs
- Access responsive customer support when you need it
- Enjoy fast shipping directly to your location
- Benefit from extensive industry knowledge—75+ years of experience
- In-house gas detection calibration & repair services available

