ISG Demand Flow Regulator w/Tubing
We proudly serve diverse industries including construction, oil and gas, confined space operations, manufacturing, and more. Contact our California-based safety experts or give them a call for personalized guidance on your safety needs.
Description
Description
The ISG Demand Flow Regulator delivers calibration gas on demand to pumped gas detectors and docking stations. Pair it with instruments whose internal pump pulls gas as needed — the regulator opens only when the instrument demands flow, so you use just the amount of test gas required and stretch an expensive calibration cylinder across more bump tests.
Key Specifications:
- Flow: On demand (pumped instruments / docking stations)
- Valve inlet: C-10 (fits ISG 20L, 34L, 58L, 103L, FX75, FX120 cylinders)
- Maximum cylinder pressure: 1,200 PSIG
- Material: Nickel-plated brass
- Includes: 1 ft of tubing
- Gas types: Non-reactive only
- Made in the USA
Typical pairings:
- BW IntelliDoX Docking Station (4-gas)
- IntelliDoX Docking Station for BW Clip4
- BW IntelliDoX Docking Station (Clip)
- BW GasAlert Max XT II (pump model)
- Any pumped portable gas detector or RKI/Honeywell cal station
Part Number:
R-DF
Frequently Asked Questions
When should I use a demand flow regulator instead of fixed flow?
Use demand flow for any pump-draw instrument (portable detector with an internal sampling pump) and for docking stations, because the instrument pulls exactly the gas it needs. Use fixed flow only for diffusion instruments that passively absorb gas at a defined rate. Mixing the wrong style leads to over- or under-delivery and failed calibrations.
Does this regulator work with reactive gases like H2S, Cl2, or NH3?
This regulator is rated for non-reactive gases only (4-gas mixes, CO, O2 standards, calibration methane). Reactive gases require a stainless-steel wetted-path regulator; the nickel-plated brass construction here will corrode or passivate reactive gases out of spec. Call us at 800.829.9580 for the right stainless option.
Which ISG cylinders fit the C-10 valve inlet?
The C-10 inlet fits ISG 20L, 34L, 58L, 103L, FX75, and FX120 aluminum cylinders — the standard disposable sizes PK Safety stocks for 4-gas calibration. It does not fit high-pressure steel cylinders (CGA 600); for those, use the High Pressure Fixed Flow Regulator.
Is the tubing replaceable?
Yes — the 1 ft of included tubing is standard 1/8" Tygon that any lab-supply source sells by the foot. Replace the tubing if it hardens, cracks, or absorbs odors, which can happen with heavy use or after exposure to reactive calibration gases.
Related Searches:
Calibration Gas, Gas Detection, Gas Detector Accessories, Intermountain Specialty Gases, Regulators
Specifications
Specifications
-
Product Weight (lbs.)
-
Height (in.)
-
Length (in.)
-
Width (in.)
-
Country of Origin
Reviews
Reviews
Keep your team protected & compliant!
- Expert guidance tailored to your specific needs
- Access responsive customer support when you need it
- Enjoy fast shipping directly to your location
- Benefit from extensive industry knowledge—75+ years of experience
- In-house gas detection calibration & repair services available