Expert Guidance Monday-Friday, 6:30am-4pm PST. Call Now! Request a Quote Click Here!

SKU: RKI01-65-2650XL

RKI M2A-XL MPS type LEL Sensor/Transmitter with J-Box 65-2650XL

$2,019.23

Ships in 6 - 8 weeks

Description

RKI M2A-XL Molecular Property Spectrometer (MPS) LEL Sensor/Transmitter is an explosion-proof transmitter that can operate as a standalone system or as part of a system connected with an analog or digital signal to a controller, PLC, or DCS. The M2A-XL utilizes a magnetic wand technique for performing non-intrusive calibration. The housing does not need to be opened for zeroing or calibration.

RKI’s Molecular Property Spectrometer LEL Sensor internally identifies the gas or gases being detected and applies the appropriate LEL conversion factor, allowing it to read a variety of flammable gases or vapors correctly using only a methane calibration gas. Capable of detecting over a dozen different combustible gases simultaneously — including Hydrogen — the MPS sensor is designed for reliability, accuracy, and worker safety in demanding fixed-gas applications. Expected sensor life is over 10 years in normal applications.

Key Features:

  • Direct digital readout
  • Explosion-proof housing
  • Operates independently or with any controller, PLC, or DCS
  • 4–20 mA transmitter output (65-2650RK)
  • Digital Modbus output
  • Operates from 10–30 VDC
  • 2 programmable alarm relays plus fail relay
  • Auto zero drift correction
  • Non-intrusive calibration via magnetic wand

Sensor Features:

  • Responds accurately to over 14 combustible gases with calibration to methane only
  • No gas-specific conversion factors required
  • Immune to sensor poisons including H2S, silicone, and HCFCs
  • Requires only annual field response checks
  • Suitable for use in high humidity conditions
  • Explosion-proof approval CULUS
  • Long sensor life (10+ years in normal applications)
  • Two-year warranty on the sensor (1 year on electronics)

Applications:

  • Environments where silicone contamination is present
  • High humidity applications where IR or catalytic sensing may not hold up
  • Locations where a mixture of hydrocarbons could be present
  • H2 applications where catalytic sensor poisoning is a concern

Specification Sheet:

Specification Sheet

Part Number:
65-2650XL – LEL, M2A-XL, MPS-type sensor/transmitter with J-Box

Frequently Asked Questions

How does the Molecular Property Spectrometer (MPS) sensor differ from catalytic bead sensors?

Traditional catalytic bead (pellistor) sensors rely on the oxidation of combustible gas on a platinum filament to measure LEL. They are susceptible to poisoning by silicone compounds, H2S, and HCFCs, and they require gas-specific conversion factors for each hydrocarbon. The MPS sensor uses infrared-based molecular property analysis to internally identify the gas being detected and apply the correct LEL conversion factor automatically. This means accurate readings across 14+ combustible gases with a single methane calibration, and immunity to common catalyst poisons, resulting in a significantly longer service life.

What combustible gases can the M2A-XL MPS sensor detect?

The M2A-XL MPS sensor responds accurately to over 14 combustible gases with a single methane calibration — including methane, propane, butane, ethylene, hydrogen, isobutylene, and many other hydrocarbons. No gas-specific conversion factors are required. For a full list of gases the MPS responds to, refer to the Specification Sheet linked above or call PK Safety at 800.829.9580.

What is the expected lifespan of the MPS sensor in the M2A-XL?

RKI rates the MPS sensor for over 10 years of service life in normal applications, significantly outlasting conventional catalytic bead sensors that typically require replacement every 2–4 years. The sensor also requires only annual field response checks rather than quarterly calibration, reducing both maintenance labor and calibration gas consumption over the life of the installation. The transmitter electronics carry a 1-year warranty; the sensor carries a 2-year warranty.

How does non-intrusive calibration work on the M2A-XL?

The M2A-XL uses a magnetic wand technique to activate the calibration mode from outside the housing. No tools and no housing entry are required for zeroing or span calibration — a significant safety and operational advantage in classified locations, because the housing can remain closed and sealed while calibration is performed. This reduces the risk of introducing ignition sources or moisture into the explosion-proof enclosure during calibration.

Does PK Safety integrate or service RKI M2A-XL transmitters?

PK Safety services RKI instruments in-house with factory-trained technicians, including the M2A-XL MPS transmitter. We support integration with RKI controllers including the Beacon 800 and Beacon 410A, and with third-party PLC/DCS systems via 4–20 mA or Modbus. Call our fixed-gas detection specialists at 800.829.9580 for installation guidance, controller compatibility questions, or service scheduling.

What applications benefit most from MPS-type LEL sensing?

MPS sensing excels in environments hostile to catalytic bead sensors: facilities with silicone-based compounds (semiconductor fabs, HVAC shops), high-humidity industrial settings (wastewater plants, chemical process areas), locations with mixed hydrocarbon streams where a single calibration gas must cover many target gases, and H2 applications such as battery rooms, fuel cell facilities, or hydrogen generation plants where silicone and H2S poisoning of conventional pellistors is a documented problem. See PK Safety’s fixed gas detectors collection for related products.

Related Searches
Fixed Gas Detectors, Gas Detection

Read more

RKI M2A-XL Molecular Property Spectrometer (MPS) LEL Sensor/Transmitter is an explosion-proof transmitter that can operate as a standalone system or as part of a system connected with an analog or digital signal to a controller, PLC, or DCS. The M2A-XL utilizes a magnetic wand technique for performing non-intrusive calibration. The housing does not need to be opened for zeroing or calibration.

RKI’s Molecular Property Spectrometer LEL Sensor internally identifies the gas or gases being detected and applies the appropriate LEL conversion factor, allowing it to read a variety of flammable gases or vapors correctly using only a methane calibration gas. Capable of detecting over a dozen different combustible gases simultaneously — including Hydrogen — the MPS sensor is designed for reliability, accuracy, and worker safety in demanding fixed-gas applications. Expected sensor life is over 10 years in normal applications.

Key Features:

  • Direct digital readout
  • Explosion-proof housing
  • Operates independently or with any controller, PLC, or DCS
  • 4–20 mA transmitter output (65-2650RK)
  • Digital Modbus output
  • Operates from 10–30 VDC
  • 2 programmable alarm relays plus fail relay
  • Auto zero drift correction
  • Non-intrusive calibration via magnetic wand

Sensor Features:

  • Responds accurately to over 14 combustible gases with calibration to methane only
  • No gas-specific conversion factors required
  • Immune to sensor poisons including H2S, silicone, and HCFCs
  • Requires only annual field response checks
  • Suitable for use in high humidity conditions
  • Explosion-proof approval CULUS
  • Long sensor life (10+ years in normal applications)
  • Two-year warranty on the sensor (1 year on electronics)

Applications:

  • Environments where silicone contamination is present
  • High humidity applications where IR or catalytic sensing may not hold up
  • Locations where a mixture of hydrocarbons could be present
  • H2 applications where catalytic sensor poisoning is a concern

Specification Sheet:

Specification Sheet

Part Number:
65-2650XL – LEL, M2A-XL, MPS-type sensor/transmitter with J-Box

Frequently Asked Questions

How does the Molecular Property Spectrometer (MPS) sensor differ from catalytic bead sensors?

Traditional catalytic bead (pellistor) sensors rely on the oxidation of combustible gas on a platinum filament to measure LEL. They are susceptible to poisoning by silicone compounds, H2S, and HCFCs, and they require gas-specific conversion factors for each hydrocarbon. The MPS sensor uses infrared-based molecular property analysis to internally identify the gas being detected and apply the correct LEL conversion factor automatically. This means accurate readings across 14+ combustible gases with a single methane calibration, and immunity to common catalyst poisons, resulting in a significantly longer service life.

What combustible gases can the M2A-XL MPS sensor detect?

The M2A-XL MPS sensor responds accurately to over 14 combustible gases with a single methane calibration — including methane, propane, butane, ethylene, hydrogen, isobutylene, and many other hydrocarbons. No gas-specific conversion factors are required. For a full list of gases the MPS responds to, refer to the Specification Sheet linked above or call PK Safety at 800.829.9580.

What is the expected lifespan of the MPS sensor in the M2A-XL?

RKI rates the MPS sensor for over 10 years of service life in normal applications, significantly outlasting conventional catalytic bead sensors that typically require replacement every 2–4 years. The sensor also requires only annual field response checks rather than quarterly calibration, reducing both maintenance labor and calibration gas consumption over the life of the installation. The transmitter electronics carry a 1-year warranty; the sensor carries a 2-year warranty.

How does non-intrusive calibration work on the M2A-XL?

The M2A-XL uses a magnetic wand technique to activate the calibration mode from outside the housing. No tools and no housing entry are required for zeroing or span calibration — a significant safety and operational advantage in classified locations, because the housing can remain closed and sealed while calibration is performed. This reduces the risk of introducing ignition sources or moisture into the explosion-proof enclosure during calibration.

Does PK Safety integrate or service RKI M2A-XL transmitters?

PK Safety services RKI instruments in-house with factory-trained technicians, including the M2A-XL MPS transmitter. We support integration with RKI controllers including the Beacon 800 and Beacon 410A, and with third-party PLC/DCS systems via 4–20 mA or Modbus. Call our fixed-gas detection specialists at 800.829.9580 for installation guidance, controller compatibility questions, or service scheduling.

What applications benefit most from MPS-type LEL sensing?

MPS sensing excels in environments hostile to catalytic bead sensors: facilities with silicone-based compounds (semiconductor fabs, HVAC shops), high-humidity industrial settings (wastewater plants, chemical process areas), locations with mixed hydrocarbon streams where a single calibration gas must cover many target gases, and H2 applications such as battery rooms, fuel cell facilities, or hydrogen generation plants where silicone and H2S poisoning of conventional pellistors is a documented problem. See PK Safety’s fixed gas detectors collection for related products.

Related Searches
Fixed Gas Detectors, Gas Detection

Specifications

  • Product Weight (lbs.)
    7
  • Height (in.)
    1
  • Length (in.)
    12
  • Width (in.)
    8.5
  • Country of Origin
    JP
  • Warranty Info
    Warranty Included

Reviews

Keep your team protected & compliant!

  • Expert guidance tailored to your specific needs
  • Access responsive customer support when you need it
  • Enjoy fast shipping directly to your location
  • Benefit from extensive industry knowledge—75+ years of experience
  • In-house gas detection calibration & repair services available
Close-up of the RKI M2A-XL MPS type LEL Sensor/Transmitter with J-Box 65-2650XL featuring a circular gray metal casing and a transparent cover revealing internal components. A digital display on the circuit board reads "RKI Instruments Long Beach, CA USA." An LEL sensor and explosion-proof transmitter are integrated, with a sensor extending from the side.
RKI Instruments

RKI M2A-XL MPS type LEL Sensor/Transmitter with J-Box 65-2650XL

$2,019.23

RKI M2A-XL Molecular Property Spectrometer (MPS) LEL Sensor/Transmitter is an explosion-proof transmitter that can operate as a standalone system or as part of a system connected with an analog or digital signal to a controller, PLC, or DCS. The M2A-XL utilizes a magnetic wand technique for performing non-intrusive calibration. The housing does not need to be opened for zeroing or calibration.

RKI’s Molecular Property Spectrometer LEL Sensor internally identifies the gas or gases being detected and applies the appropriate LEL conversion factor, allowing it to read a variety of flammable gases or vapors correctly using only a methane calibration gas. Capable of detecting over a dozen different combustible gases simultaneously — including Hydrogen — the MPS sensor is designed for reliability, accuracy, and worker safety in demanding fixed-gas applications. Expected sensor life is over 10 years in normal applications.

Key Features:

Sensor Features:

Applications:

Specification Sheet:

Specification Sheet

Part Number:
65-2650XL – LEL, M2A-XL, MPS-type sensor/transmitter with J-Box

Frequently Asked Questions

How does the Molecular Property Spectrometer (MPS) sensor differ from catalytic bead sensors?

Traditional catalytic bead (pellistor) sensors rely on the oxidation of combustible gas on a platinum filament to measure LEL. They are susceptible to poisoning by silicone compounds, H2S, and HCFCs, and they require gas-specific conversion factors for each hydrocarbon. The MPS sensor uses infrared-based molecular property analysis to internally identify the gas being detected and apply the correct LEL conversion factor automatically. This means accurate readings across 14+ combustible gases with a single methane calibration, and immunity to common catalyst poisons, resulting in a significantly longer service life.

What combustible gases can the M2A-XL MPS sensor detect?

The M2A-XL MPS sensor responds accurately to over 14 combustible gases with a single methane calibration — including methane, propane, butane, ethylene, hydrogen, isobutylene, and many other hydrocarbons. No gas-specific conversion factors are required. For a full list of gases the MPS responds to, refer to the Specification Sheet linked above or call PK Safety at 800.829.9580.

What is the expected lifespan of the MPS sensor in the M2A-XL?

RKI rates the MPS sensor for over 10 years of service life in normal applications, significantly outlasting conventional catalytic bead sensors that typically require replacement every 2–4 years. The sensor also requires only annual field response checks rather than quarterly calibration, reducing both maintenance labor and calibration gas consumption over the life of the installation. The transmitter electronics carry a 1-year warranty; the sensor carries a 2-year warranty.

How does non-intrusive calibration work on the M2A-XL?

The M2A-XL uses a magnetic wand technique to activate the calibration mode from outside the housing. No tools and no housing entry are required for zeroing or span calibration — a significant safety and operational advantage in classified locations, because the housing can remain closed and sealed while calibration is performed. This reduces the risk of introducing ignition sources or moisture into the explosion-proof enclosure during calibration.

Does PK Safety integrate or service RKI M2A-XL transmitters?

PK Safety services RKI instruments in-house with factory-trained technicians, including the M2A-XL MPS transmitter. We support integration with RKI controllers including the Beacon 800 and Beacon 410A, and with third-party PLC/DCS systems via 4–20 mA or Modbus. Call our fixed-gas detection specialists at 800.829.9580 for installation guidance, controller compatibility questions, or service scheduling.

What applications benefit most from MPS-type LEL sensing?

MPS sensing excels in environments hostile to catalytic bead sensors: facilities with silicone-based compounds (semiconductor fabs, HVAC shops), high-humidity industrial settings (wastewater plants, chemical process areas), locations with mixed hydrocarbon streams where a single calibration gas must cover many target gases, and H2 applications such as battery rooms, fuel cell facilities, or hydrogen generation plants where silicone and H2S poisoning of conventional pellistors is a documented problem. See PK Safety’s fixed gas detectors collection for related products.

Related Searches
Fixed Gas Detectors, Gas Detection

View product