Expert Guidance Monday-Friday, 6:30am-4pm PST. Call Now! Request a Quote Click Here!

SKU: RKI01-81-0143RK-04

RKI Isobutylene/H2S/CO/CH4 50% LEL/O2 81-0143RK-04

$402.14

Ships in 5 - 7 days

Description

The RKI Isobutylene / H2S / CO / CH4 / O2 Calibration Gas Mixture (81-0143RK-04) is a precision five-gas blend in a 34-liter aluminum cylinder, designed for calibration and verification of the RKI GX-6100 and SDM-6100 multi-gas detection systems configured with an isobutylene PID sensor option.

Gas Mixture: Isobutylene / H2S 25 ppm / CO 50 ppm / CH4 50% LEL / O2 12% in nitrogen

Note: This item ships via UPS Ground due to HazMat restrictions and is not available for expedited shipping. Calibration gas is not returnable. Please check your selection carefully before ordering.

Compatible with the following RKI monitors:

Part Number:
81-0143RK-04

PK Safety services RKI Instruments gas monitors in-house with factory-trained technicians — calibration, sensor replacement, bump testing, and full repair. Call 800.829.9580 to speak with a technician.

Related Searches
Calibration Gas, Gas Detection

Frequently Asked Questions

What is isobutylene used for in this calibration gas?

Isobutylene is used as the PID (photoionization detector) sensor calibration reference in the GX-6100 when configured for VOC detection. The PID sensor responds to volatile organic compounds, and isobutylene is a standard reference compound used to span the PID response. This blend calibrates both the PID and the electrochemical gas sensors (H2S, CO, O2) in a single gas application.

Is 81-0143RK-04 compatible with other RKI monitors that have PID sensors?

This specific mix is listed for the GX-6100 and SDM-6100. Compatibility with other monitors — such as the GX-6000 or GX-Force with a PID option — depends on the sensor configuration and the concentrations specified in those monitors' calibration procedures. Call 800.829.9580 and reference the monitor model and sensor kit part number for a compatibility check.

How does this mix differ from the standard 81-0154RK-04 four-gas mix?

The standard 81-0154RK-04 contains H2S, CO, CH4, and O2 — for four-gas monitors without a PID. The 81-0143RK-04 adds isobutylene as a fifth component for PID sensor calibration. Do not interchange these mixes unless the monitor's calibration procedure explicitly allows it.

Why is calibration gas non-returnable?

Calibration gas is a hazardous material with a traceable certification lot. Once shipped, cylinders cannot be re-inspected or restocked. Confirm the monitor model and sensor configuration before placing an order. Call 800.829.9580 to verify compatibility before purchasing.

How should the 34-liter cylinder be stored?

Store upright in a cool, dry, ventilated area away from heat sources and incompatible materials. Secure the cylinder to prevent tipping. H2S-containing blends are reactive with certain metals — use the regulator supplied or recommended by RKI. Do not store in a vehicle or enclosed space without proper ventilation.

Can PK Safety service or calibrate the GX-6100?

Yes. PK Safety services RKI Instruments monitors in-house with factory-trained technicians, including the GX-6100 series. Services include PID sensor calibration and replacement, electrochemical sensor replacement, and full functional testing. Call 800.829.9580 to arrange service or request a return authorization.

Read more

The RKI Isobutylene / H2S / CO / CH4 / O2 Calibration Gas Mixture (81-0143RK-04) is a precision five-gas blend in a 34-liter aluminum cylinder, designed for calibration and verification of the RKI GX-6100 and SDM-6100 multi-gas detection systems configured with an isobutylene PID sensor option.

Gas Mixture: Isobutylene / H2S 25 ppm / CO 50 ppm / CH4 50% LEL / O2 12% in nitrogen

Note: This item ships via UPS Ground due to HazMat restrictions and is not available for expedited shipping. Calibration gas is not returnable. Please check your selection carefully before ordering.

Compatible with the following RKI monitors:

Part Number:
81-0143RK-04

PK Safety services RKI Instruments gas monitors in-house with factory-trained technicians — calibration, sensor replacement, bump testing, and full repair. Call 800.829.9580 to speak with a technician.

Related Searches
Calibration Gas, Gas Detection

Frequently Asked Questions

What is isobutylene used for in this calibration gas?

Isobutylene is used as the PID (photoionization detector) sensor calibration reference in the GX-6100 when configured for VOC detection. The PID sensor responds to volatile organic compounds, and isobutylene is a standard reference compound used to span the PID response. This blend calibrates both the PID and the electrochemical gas sensors (H2S, CO, O2) in a single gas application.

Is 81-0143RK-04 compatible with other RKI monitors that have PID sensors?

This specific mix is listed for the GX-6100 and SDM-6100. Compatibility with other monitors — such as the GX-6000 or GX-Force with a PID option — depends on the sensor configuration and the concentrations specified in those monitors' calibration procedures. Call 800.829.9580 and reference the monitor model and sensor kit part number for a compatibility check.

How does this mix differ from the standard 81-0154RK-04 four-gas mix?

The standard 81-0154RK-04 contains H2S, CO, CH4, and O2 — for four-gas monitors without a PID. The 81-0143RK-04 adds isobutylene as a fifth component for PID sensor calibration. Do not interchange these mixes unless the monitor's calibration procedure explicitly allows it.

Why is calibration gas non-returnable?

Calibration gas is a hazardous material with a traceable certification lot. Once shipped, cylinders cannot be re-inspected or restocked. Confirm the monitor model and sensor configuration before placing an order. Call 800.829.9580 to verify compatibility before purchasing.

How should the 34-liter cylinder be stored?

Store upright in a cool, dry, ventilated area away from heat sources and incompatible materials. Secure the cylinder to prevent tipping. H2S-containing blends are reactive with certain metals — use the regulator supplied or recommended by RKI. Do not store in a vehicle or enclosed space without proper ventilation.

Can PK Safety service or calibrate the GX-6100?

Yes. PK Safety services RKI Instruments monitors in-house with factory-trained technicians, including the GX-6100 series. Services include PID sensor calibration and replacement, electrochemical sensor replacement, and full functional testing. Call 800.829.9580 to arrange service or request a return authorization.

Specifications

  • MPN
    81-0143RK-04
  • Gas Type
    Isobutylene/H2S/CO/CH4 50% LEL/O2
  • Product Weight (lbs.)
    1
  • Country of Origin
    US

Reviews

Keep your team protected & compliant!

  • Expert guidance tailored to your specific needs
  • Access responsive customer support when you need it
  • Enjoy fast shipping directly to your location
  • Benefit from extensive industry knowledge—75+ years of experience
  • In-house gas detection calibration & repair services available
A silver RKI Instruments gas cylinder with a white label displays calibration gas details for the RKI Isobutylene/H2S/CO/CH4 50% LEL/O2 81-0143RK-04, shown upright with a rounded top and no valve or regulator attached.
RKI Instruments

RKI Isobutylene/H2S/CO/CH4 50% LEL/O2 81-0143RK-04

$402.14

The RKI Isobutylene / H2S / CO / CH4 / O2 Calibration Gas Mixture (81-0143RK-04) is a precision five-gas blend in a 34-liter aluminum cylinder, designed for calibration and verification of the RKI GX-6100 and SDM-6100 multi-gas detection systems configured with an isobutylene PID sensor option.

Gas Mixture: Isobutylene / H2S 25 ppm / CO 50 ppm / CH4 50% LEL / O2 12% in nitrogen

Note: This item ships via UPS Ground due to HazMat restrictions and is not available for expedited shipping. Calibration gas is not returnable. Please check your selection carefully before ordering.

Compatible with the following RKI monitors:

Part Number:
81-0143RK-04

PK Safety services RKI Instruments gas monitors in-house with factory-trained technicians — calibration, sensor replacement, bump testing, and full repair. Call 800.829.9580 to speak with a technician.

Related Searches
Calibration Gas, Gas Detection

Frequently Asked Questions

What is isobutylene used for in this calibration gas?

Isobutylene is used as the PID (photoionization detector) sensor calibration reference in the GX-6100 when configured for VOC detection. The PID sensor responds to volatile organic compounds, and isobutylene is a standard reference compound used to span the PID response. This blend calibrates both the PID and the electrochemical gas sensors (H2S, CO, O2) in a single gas application.

Is 81-0143RK-04 compatible with other RKI monitors that have PID sensors?

This specific mix is listed for the GX-6100 and SDM-6100. Compatibility with other monitors — such as the GX-6000 or GX-Force with a PID option — depends on the sensor configuration and the concentrations specified in those monitors' calibration procedures. Call 800.829.9580 and reference the monitor model and sensor kit part number for a compatibility check.

How does this mix differ from the standard 81-0154RK-04 four-gas mix?

The standard 81-0154RK-04 contains H2S, CO, CH4, and O2 — for four-gas monitors without a PID. The 81-0143RK-04 adds isobutylene as a fifth component for PID sensor calibration. Do not interchange these mixes unless the monitor's calibration procedure explicitly allows it.

Why is calibration gas non-returnable?

Calibration gas is a hazardous material with a traceable certification lot. Once shipped, cylinders cannot be re-inspected or restocked. Confirm the monitor model and sensor configuration before placing an order. Call 800.829.9580 to verify compatibility before purchasing.

How should the 34-liter cylinder be stored?

Store upright in a cool, dry, ventilated area away from heat sources and incompatible materials. Secure the cylinder to prevent tipping. H2S-containing blends are reactive with certain metals — use the regulator supplied or recommended by RKI. Do not store in a vehicle or enclosed space without proper ventilation.

Can PK Safety service or calibrate the GX-6100?

Yes. PK Safety services RKI Instruments monitors in-house with factory-trained technicians, including the GX-6100 series. Services include PID sensor calibration and replacement, electrochemical sensor replacement, and full functional testing. Call 800.829.9580 to arrange service or request a return authorization.

View product