Description
RKI Instruments SC-04 Series Cl2 Single Gas Monitor is a single-gas toxic personal monitor designed to operate for many years with field replaceable sensors and filters. With a protective rubber boot and an IP-67 rating, the SC-04 Cl2 with a 1-year warranty is built for long-term use in chlorine-exposure environments.
Applications: Hazardous material response, Mining, Refineries/petrochemical, Water/wastewater treatment, Pharmaceuticals, Utilities, Chemical plants, Fire Services
Key Features:
- Personal monitoring for Cl2 (chlorine gas)
- Operates 3,000 hours on replaceable alkaline batteries
- Digital LCD readout
- Easy power on/off via single Power Mode button
- Pocket size: 2.1"(W) x 2.6"(H) x 0.9"(D)
- Lightweight: 2.8 ounces
- Impact, dust, and water resistant (IP-67)
- Replaceable rubber boot
- Alligator clip with 360° rotation
- Data log: 10 to 600 hours with adjustable intervals
- Audible / visual / vibration alarms
- Automatic backlight
- Low battery alarm
- Intrinsically safe, ATEX and C/US approvals
- 1-year warranty
Specifications:
- Gas Detected: Chlorine (Cl2)
- Detection principle: Electrochemical
- Detection range: 0 ~ 20.00 ppm (0.05 ppm resolution)
- Alarm set points: 1st: 1.00 ppm, 2nd: 2.00 ppm, 3rd: 10.00 ppm, TWA: 0.5 ppm, STEL: 1 ppm
- Alarm types: Gas alarms: 1st, 2nd, and 3rd (user adjustable), OVER alarm, STEL and TWA; Trouble alarms: Sensor connection, low battery, circuit failure, and calibration range error
- Gas sampling: Diffusion
- Response time: T90 in 10 seconds
- Accuracy: ± 10% of reading or ± 5% of full scale (whichever is greater)
- Data logging: 10-second intervals = 5 hours; 5-minute intervals = 150 hours; 10-minute intervals = 300 hours. Records alarms, alarm trends, gas readings, calibration & bump test history, instrument information and settings.
- Continuous operation: 3,000 hours on alkaline dry cell (at 25°C, no backlight)
- Safety rating: ATEX/IECEx approved; QPS classified C/US intrinsically safe, Class I, Division 1, Groups A, B, C, D
- Enclosure: IP-67 dust and water resistant
- Display: Digital LCD readout, gas name & concentration, auto backlighting during alarm, battery icon
Monitor Includes:
- Rubber protective boot
- Alkaline batteries (2-AAA size)
- Alligator clip
- Data log software
Optional Accessory:
Downloading cable / USB–IrDA adapter
Specification Sheet:
SC-04 Manual:
04 Series User Setup Program Operator's Manual:
04 Series Data Logger Management Program Operator's Manual:
Part Number:
73-0075
Related Searches
Gas Detection,
Single-Gas Monitors
Frequently Asked Questions
What is the detection range of the SC-04 Cl2 monitor?
The SC-04 Cl2 detects chlorine gas from 0 to 20.00 ppm at 0.05 ppm resolution. Alarm setpoints are preset at 1.00 ppm (1st alarm), 2.00 ppm (2nd alarm), and 10.00 ppm (3rd alarm). TWA is 0.5 ppm and STEL is 1 ppm, consistent with OSHA's permissible exposure limit for chlorine.
Where is chlorine gas exposure a hazard at work?
Chlorine is used in water and wastewater treatment, paper and pulp bleaching, chemical synthesis, pool and spa maintenance, and food-grade sanitation. Workers in these environments need personal Cl2 monitors to remain within OSHA's permissible exposure limit and to receive early warning of accidental releases.
How long does the SC-04 Cl2 operate on batteries?
Two standard AAA alkaline batteries power the SC-04 Cl2 for up to 3,000 hours of continuous operation at 25°C with the backlight off. Batteries are field-replaceable and a low-battery alarm activates before power is depleted.
Is the SC-04 Cl2 approved for use in hazardous classified locations?
Yes. The SC-04 Cl2 carries ATEX/IECEx certification and is QPS classified as intrinsically safe, Class I, Division 1, Groups A, B, C, D under C/US. The IP-67 rated enclosure resists dust and water immersion for installations in wet industrial environments.
What data does the SC-04 Cl2 log?
The SC-04 Cl2 logs gas concentration readings at intervals from 10 seconds to 10 minutes, storing up to 300 hours of data. It records alarm events, alarm trends, calibration history, bump test history, and instrument settings. Download recorded data using the optional USB/IrDA cable and included data logging software.
Read more
Description
RKI Instruments SC-04 Series Cl2 Single Gas Monitor is a single-gas toxic personal monitor designed to operate for many years with field replaceable sensors and filters. With a protective rubber boot and an IP-67 rating, the SC-04 Cl2 with a 1-year warranty is built for long-term use in chlorine-exposure environments.
Applications: Hazardous material response, Mining, Refineries/petrochemical, Water/wastewater treatment, Pharmaceuticals, Utilities, Chemical plants, Fire Services
Key Features:
- Personal monitoring for Cl2 (chlorine gas)
- Operates 3,000 hours on replaceable alkaline batteries
- Digital LCD readout
- Easy power on/off via single Power Mode button
- Pocket size: 2.1"(W) x 2.6"(H) x 0.9"(D)
- Lightweight: 2.8 ounces
- Impact, dust, and water resistant (IP-67)
- Replaceable rubber boot
- Alligator clip with 360° rotation
- Data log: 10 to 600 hours with adjustable intervals
- Audible / visual / vibration alarms
- Automatic backlight
- Low battery alarm
- Intrinsically safe, ATEX and C/US approvals
- 1-year warranty
Specifications:
- Gas Detected: Chlorine (Cl2)
- Detection principle: Electrochemical
- Detection range: 0 ~ 20.00 ppm (0.05 ppm resolution)
- Alarm set points: 1st: 1.00 ppm, 2nd: 2.00 ppm, 3rd: 10.00 ppm, TWA: 0.5 ppm, STEL: 1 ppm
- Alarm types: Gas alarms: 1st, 2nd, and 3rd (user adjustable), OVER alarm, STEL and TWA; Trouble alarms: Sensor connection, low battery, circuit failure, and calibration range error
- Gas sampling: Diffusion
- Response time: T90 in 10 seconds
- Accuracy: ± 10% of reading or ± 5% of full scale (whichever is greater)
- Data logging: 10-second intervals = 5 hours; 5-minute intervals = 150 hours; 10-minute intervals = 300 hours. Records alarms, alarm trends, gas readings, calibration & bump test history, instrument information and settings.
- Continuous operation: 3,000 hours on alkaline dry cell (at 25°C, no backlight)
- Safety rating: ATEX/IECEx approved; QPS classified C/US intrinsically safe, Class I, Division 1, Groups A, B, C, D
- Enclosure: IP-67 dust and water resistant
- Display: Digital LCD readout, gas name & concentration, auto backlighting during alarm, battery icon
Monitor Includes:
- Rubber protective boot
- Alkaline batteries (2-AAA size)
- Alligator clip
- Data log software
Optional Accessory: Downloading cable / USB–IrDA adapter
Specification Sheet:
SC-04 Manual:
04 Series User Setup Program Operator's Manual:
04 Series Data Logger Management Program Operator's Manual:
Part Number:
73-0075
Related Searches
Gas Detection,
Single-Gas Monitors
Frequently Asked Questions
What is the detection range of the SC-04 Cl2 monitor?
The SC-04 Cl2 detects chlorine gas from 0 to 20.00 ppm at 0.05 ppm resolution. Alarm setpoints are preset at 1.00 ppm (1st alarm), 2.00 ppm (2nd alarm), and 10.00 ppm (3rd alarm). TWA is 0.5 ppm and STEL is 1 ppm, consistent with OSHA's permissible exposure limit for chlorine.
Where is chlorine gas exposure a hazard at work?
Chlorine is used in water and wastewater treatment, paper and pulp bleaching, chemical synthesis, pool and spa maintenance, and food-grade sanitation. Workers in these environments need personal Cl2 monitors to remain within OSHA's permissible exposure limit and to receive early warning of accidental releases.
How long does the SC-04 Cl2 operate on batteries?
Two standard AAA alkaline batteries power the SC-04 Cl2 for up to 3,000 hours of continuous operation at 25°C with the backlight off. Batteries are field-replaceable and a low-battery alarm activates before power is depleted.
Is the SC-04 Cl2 approved for use in hazardous classified locations?
Yes. The SC-04 Cl2 carries ATEX/IECEx certification and is QPS classified as intrinsically safe, Class I, Division 1, Groups A, B, C, D under C/US. The IP-67 rated enclosure resists dust and water immersion for installations in wet industrial environments.
What data does the SC-04 Cl2 log?
The SC-04 Cl2 logs gas concentration readings at intervals from 10 seconds to 10 minutes, storing up to 300 hours of data. It records alarm events, alarm trends, calibration history, bump test history, and instrument settings. Download recorded data using the optional USB/IrDA cable and included data logging software.
RKI Instruments SC-04 Series Cl2 Single Gas Monitor is a single-gas toxic personal monitor designed to operate for many years with field replaceable sensors and filters. With a protective rubber boot and an IP-67 rating, the SC-04 Cl2 with a 1-year warranty is built for long-term use in chlorine-exposure environments.
Applications: Hazardous material response, Mining, Refineries/petrochemical, Water/wastewater treatment, Pharmaceuticals, Utilities, Chemical plants, Fire Services
Key Features:
- Personal monitoring for Cl2 (chlorine gas)
- Operates 3,000 hours on replaceable alkaline batteries
- Digital LCD readout
- Easy power on/off via single Power Mode button
- Pocket size: 2.1"(W) x 2.6"(H) x 0.9"(D)
- Lightweight: 2.8 ounces
- Impact, dust, and water resistant (IP-67)
- Replaceable rubber boot
- Alligator clip with 360° rotation
- Data log: 10 to 600 hours with adjustable intervals
- Audible / visual / vibration alarms
- Automatic backlight
- Low battery alarm
- Intrinsically safe, ATEX and C/US approvals
- 1-year warranty
Specifications:
- Gas Detected: Chlorine (Cl2)
- Detection principle: Electrochemical
- Detection range: 0 ~ 20.00 ppm (0.05 ppm resolution)
- Alarm set points: 1st: 1.00 ppm, 2nd: 2.00 ppm, 3rd: 10.00 ppm, TWA: 0.5 ppm, STEL: 1 ppm
- Alarm types: Gas alarms: 1st, 2nd, and 3rd (user adjustable), OVER alarm, STEL and TWA; Trouble alarms: Sensor connection, low battery, circuit failure, and calibration range error
- Gas sampling: Diffusion
- Response time: T90 in 10 seconds
- Accuracy: ± 10% of reading or ± 5% of full scale (whichever is greater)
- Data logging: 10-second intervals = 5 hours; 5-minute intervals = 150 hours; 10-minute intervals = 300 hours. Records alarms, alarm trends, gas readings, calibration & bump test history, instrument information and settings.
- Continuous operation: 3,000 hours on alkaline dry cell (at 25°C, no backlight)
- Safety rating: ATEX/IECEx approved; QPS classified C/US intrinsically safe, Class I, Division 1, Groups A, B, C, D
- Enclosure: IP-67 dust and water resistant
- Display: Digital LCD readout, gas name & concentration, auto backlighting during alarm, battery icon
Monitor Includes:
- Rubber protective boot
- Alkaline batteries (2-AAA size)
- Alligator clip
- Data log software
Optional Accessory: Downloading cable / USB–IrDA adapter
Specification Sheet:
SC-04 Manual:
04 Series User Setup Program Operator's Manual:
04 Series Data Logger Management Program Operator's Manual:
Part Number:
73-0075
Related Searches
Gas Detection,
Single-Gas Monitors
Frequently Asked Questions
What is the detection range of the SC-04 Cl2 monitor?
The SC-04 Cl2 detects chlorine gas from 0 to 20.00 ppm at 0.05 ppm resolution. Alarm setpoints are preset at 1.00 ppm (1st alarm), 2.00 ppm (2nd alarm), and 10.00 ppm (3rd alarm). TWA is 0.5 ppm and STEL is 1 ppm, consistent with OSHA's permissible exposure limit for chlorine.
Where is chlorine gas exposure a hazard at work?
Chlorine is used in water and wastewater treatment, paper and pulp bleaching, chemical synthesis, pool and spa maintenance, and food-grade sanitation. Workers in these environments need personal Cl2 monitors to remain within OSHA's permissible exposure limit and to receive early warning of accidental releases.
How long does the SC-04 Cl2 operate on batteries?
Two standard AAA alkaline batteries power the SC-04 Cl2 for up to 3,000 hours of continuous operation at 25°C with the backlight off. Batteries are field-replaceable and a low-battery alarm activates before power is depleted.
Is the SC-04 Cl2 approved for use in hazardous classified locations?
Yes. The SC-04 Cl2 carries ATEX/IECEx certification and is QPS classified as intrinsically safe, Class I, Division 1, Groups A, B, C, D under C/US. The IP-67 rated enclosure resists dust and water immersion for installations in wet industrial environments.
What data does the SC-04 Cl2 log?
The SC-04 Cl2 logs gas concentration readings at intervals from 10 seconds to 10 minutes, storing up to 300 hours of data. It records alarm events, alarm trends, calibration history, bump test history, and instrument settings. Download recorded data using the optional USB/IrDA cable and included data logging software.
Specifications
Specifications
-
Gas Type
-
Color
-
Product Weight (lbs.)
-
Height (in.)
-
Length (in.)
-
Width (in.)
-
Country of Origin
-
Warranty Info
Reviews
Reviews
Keep your team protected & compliant!
- Expert guidance tailored to your specific needs
- Access responsive customer support when you need it
- Enjoy fast shipping directly to your location
- Benefit from extensive industry knowledge—75+ years of experience
- In-house gas detection calibration & repair services available

