Expert Guidance Monday-Friday, 6:30am-4pm PST. Call Now! Request a Quote Click Here!

SKU: RKI01-72-0018

RKI Instruments OX-04 Series O2 Single Gas Monitor 72-0018

$118.00

Ships next business day

Description

RKI Instruments OX-04 Series O2 Single Gas Monitor is a single-gas toxic personal monitor designed to operate for many years with field replaceable sensors and filters.

With a protective rubber boot and an IP-67 rating, the 04 Series with a 3 year warranty is built to operate for a long time.

Applications: Hazardous material, Mining, Refineries / petrochemical, Water / wastewater treatment, Pharmaceuticals, Utilities, Chemical plants, Fire Services

Key Features:

  • Personal monitoring for O2
  • Operates 3,000 hours on replaceable alkaline batteries
  • Digital LCD readout
  • Easy "Turn On" and "Turn Off" by pressing down on the Power Mode button
  • Pocket size 2.1"(W) x 2.6"(H) x 0.9"(D)
  • Light weight 2.8 ounces
  • Impact, dust, and water resistant (IP-67)
  • Replaceable rubber boot
  • Alligator clip with 360° rotation
  • Data log 10 to 600 hours with adjustable intervals
  • Audible / visual / vibration alarms
  • Automatic backlight
  • Low battery alarm
  • Intrinsically safe, ATEX and C / US approvals
  • 3 year warranty on material and workmanship including sensors

Specifications:

  • Gas Detected: Oxygen
  • Detection principle: Electrochemical
  • Detection range: 0 ~ 40%
  • Alarm set points: L: 19.5%, LL: 18.0%, H: 125.0%
  • Alarm types: Gas alarms: 1st, 2nd and 3rd (user adjustable), OVER alarm, STEL and TWA; Trouble alarms: Sensor connection, low battery, circuit failure, and calibration range error
  • Gas sampling: Diffusion
  • Response time: T90 in 10 seconds
  • Accuracy: <25% ±5% of reading or >25% ±3.0%
  • Data logging: 10 second intervals = 5 hours, 5 minute intervals = 150 hours, 10 minute intervals = 300 hours. Instrument records alarms, alarm trends, gas readings, calibration & bump test history, instrument information and settings.
  • Continuous operation: 4,600 hours
  • Safety rating: ATEX/IECEx approved. QPS classified, “C / US”, as intrinsically safe, Class I, Division 1, Groups A, B, C, D
  • Enclosure: Dust and water resistant with IP-67 rating
  • Display: Digital LCD readout, gas name & concentration, auto backlighting during alarm, operation icon, battery icon

Monitor Includes:

  • Rubber protective boot
  • Alkaline batteries (2-AAA size)
  • Alligator clip
  • Data log software

Optional Accessory: Downloading cable, USB / IrDA adapter

Specification Sheet:

Specification Sheet

04 Series User Setup Program Operator’s Manual:

04 Series User Setup Program Operator’s Manual

04 Series Data Logger Management Program Operator’s Manual:

04 Series Data Logger Management Program Operator’s Manual

Part Number:
72-0018

Frequently Asked Questions

What oxygen levels trigger alarms on the RKI OX-04 monitor?

The OX-04 ships with three alarm setpoints: L alarm at 19.5% O2, LL alarm at 18.0% O2, and an H alarm at 23.5% O2 for oxygen-enriched atmospheres. OSHA 29 CFR 1910.146 defines an oxygen-deficient atmosphere as any space with less than 19.5% O2 by volume — requiring permit-required confined space protocols. All setpoints are user-adjustable to align with your site safety program.

How long do alkaline batteries last in the OX-04 Series O2 monitor?

The OX-04 operates approximately 3,000 hours on a set of two AAA alkaline batteries — over four months of continuous use. The continuous operating ceiling is rated at 4,600 hours. The low battery alarm activates before the instrument reaches an unsafe operating voltage, giving workers time to replace batteries without gaps in monitoring coverage.

What applications require continuous personal oxygen monitoring?

O2 monitoring is required wherever inert gas purging, liquid nitrogen use, cryogenic processes, or incomplete combustion can displace oxygen. Common applications include laboratories, confined space entry under 29 CFR 1910.146, cryogenic environments, industrial gas storage rooms, clean rooms, and underground utility vaults. See PK Safety’s portable gas monitors collection for multi-gas options that pair O2 detection with LEL, CO, and H2S.

Does PK Safety service and calibrate RKI OX-04 monitors in-house?

PK Safety services RKI instruments in-house with factory-trained technicians, providing NIST-traceable oxygen calibration, sensor replacement, and data log retrieval for the OX-04 Series. The 04 Series warranty — 3 years including sensors — is supported through PK Safety’s service center. Call 800.829.9580 to schedule calibration or inquire about service pricing.

What intrinsic safety approval does the OX-04 Series carry?

The OX-04 is ATEX/IECEx approved and QPS classified C/US as intrinsically safe for Class I, Division 1, Groups A, B, C, D locations. Intrinsic safety certification confirms the monitor cannot produce sufficient electrical energy to ignite a flammable atmosphere, making it compliant for classified areas such as chemical plants, refineries, and petrochemical facilities. Always verify the certification label on your specific unit before deploying in classified zones.

How does the electrochemical sensor in the OX-04 detect oxygen?

Electrochemical oxygen sensors generate a small electrical current proportional to the partial pressure of oxygen diffusing through a membrane into an electrolyte solution. The sensor requires no external power to produce its signal, and the OX-04’s electrochemical cell is field-replaceable with no tools required, keeping maintenance straightforward. Response time is T90 in 10 seconds.

Related Searches
Gas Detection, O2 Gas Monitors, Portable Gas Monitors And Detectors, Rki Instruments, Single-Gas Monitors

Read more

RKI Instruments OX-04 Series O2 Single Gas Monitor is a single-gas toxic personal monitor designed to operate for many years with field replaceable sensors and filters.

With a protective rubber boot and an IP-67 rating, the 04 Series with a 3 year warranty is built to operate for a long time.

Applications: Hazardous material, Mining, Refineries / petrochemical, Water / wastewater treatment, Pharmaceuticals, Utilities, Chemical plants, Fire Services

Key Features:

  • Personal monitoring for O2
  • Operates 3,000 hours on replaceable alkaline batteries
  • Digital LCD readout
  • Easy "Turn On" and "Turn Off" by pressing down on the Power Mode button
  • Pocket size 2.1"(W) x 2.6"(H) x 0.9"(D)
  • Light weight 2.8 ounces
  • Impact, dust, and water resistant (IP-67)
  • Replaceable rubber boot
  • Alligator clip with 360° rotation
  • Data log 10 to 600 hours with adjustable intervals
  • Audible / visual / vibration alarms
  • Automatic backlight
  • Low battery alarm
  • Intrinsically safe, ATEX and C / US approvals
  • 3 year warranty on material and workmanship including sensors

Specifications:

  • Gas Detected: Oxygen
  • Detection principle: Electrochemical
  • Detection range: 0 ~ 40%
  • Alarm set points: L: 19.5%, LL: 18.0%, H: 125.0%
  • Alarm types: Gas alarms: 1st, 2nd and 3rd (user adjustable), OVER alarm, STEL and TWA; Trouble alarms: Sensor connection, low battery, circuit failure, and calibration range error
  • Gas sampling: Diffusion
  • Response time: T90 in 10 seconds
  • Accuracy: <25% ±5% of reading or >25% ±3.0%
  • Data logging: 10 second intervals = 5 hours, 5 minute intervals = 150 hours, 10 minute intervals = 300 hours. Instrument records alarms, alarm trends, gas readings, calibration & bump test history, instrument information and settings.
  • Continuous operation: 4,600 hours
  • Safety rating: ATEX/IECEx approved. QPS classified, “C / US”, as intrinsically safe, Class I, Division 1, Groups A, B, C, D
  • Enclosure: Dust and water resistant with IP-67 rating
  • Display: Digital LCD readout, gas name & concentration, auto backlighting during alarm, operation icon, battery icon

Monitor Includes:

  • Rubber protective boot
  • Alkaline batteries (2-AAA size)
  • Alligator clip
  • Data log software

Optional Accessory: Downloading cable, USB / IrDA adapter

Specification Sheet:

Specification Sheet

04 Series User Setup Program Operator’s Manual:

04 Series User Setup Program Operator’s Manual

04 Series Data Logger Management Program Operator’s Manual:

04 Series Data Logger Management Program Operator’s Manual

Part Number:
72-0018

Frequently Asked Questions

What oxygen levels trigger alarms on the RKI OX-04 monitor?

The OX-04 ships with three alarm setpoints: L alarm at 19.5% O2, LL alarm at 18.0% O2, and an H alarm at 23.5% O2 for oxygen-enriched atmospheres. OSHA 29 CFR 1910.146 defines an oxygen-deficient atmosphere as any space with less than 19.5% O2 by volume — requiring permit-required confined space protocols. All setpoints are user-adjustable to align with your site safety program.

How long do alkaline batteries last in the OX-04 Series O2 monitor?

The OX-04 operates approximately 3,000 hours on a set of two AAA alkaline batteries — over four months of continuous use. The continuous operating ceiling is rated at 4,600 hours. The low battery alarm activates before the instrument reaches an unsafe operating voltage, giving workers time to replace batteries without gaps in monitoring coverage.

What applications require continuous personal oxygen monitoring?

O2 monitoring is required wherever inert gas purging, liquid nitrogen use, cryogenic processes, or incomplete combustion can displace oxygen. Common applications include laboratories, confined space entry under 29 CFR 1910.146, cryogenic environments, industrial gas storage rooms, clean rooms, and underground utility vaults. See PK Safety’s portable gas monitors collection for multi-gas options that pair O2 detection with LEL, CO, and H2S.

Does PK Safety service and calibrate RKI OX-04 monitors in-house?

PK Safety services RKI instruments in-house with factory-trained technicians, providing NIST-traceable oxygen calibration, sensor replacement, and data log retrieval for the OX-04 Series. The 04 Series warranty — 3 years including sensors — is supported through PK Safety’s service center. Call 800.829.9580 to schedule calibration or inquire about service pricing.

What intrinsic safety approval does the OX-04 Series carry?

The OX-04 is ATEX/IECEx approved and QPS classified C/US as intrinsically safe for Class I, Division 1, Groups A, B, C, D locations. Intrinsic safety certification confirms the monitor cannot produce sufficient electrical energy to ignite a flammable atmosphere, making it compliant for classified areas such as chemical plants, refineries, and petrochemical facilities. Always verify the certification label on your specific unit before deploying in classified zones.

How does the electrochemical sensor in the OX-04 detect oxygen?

Electrochemical oxygen sensors generate a small electrical current proportional to the partial pressure of oxygen diffusing through a membrane into an electrolyte solution. The sensor requires no external power to produce its signal, and the OX-04’s electrochemical cell is field-replaceable with no tools required, keeping maintenance straightforward. Response time is T90 in 10 seconds.

Related Searches
Gas Detection, O2 Gas Monitors, Portable Gas Monitors And Detectors, Rki Instruments, Single-Gas Monitors

Specifications

  • Gas Type
    Oxygen (O2)
  • Product Weight (lbs.)
    2
  • Height (in.)
    2.64
  • Length (in.)
    0.94
  • Width (in.)
    2.1
  • Country of Origin
    JP
  • Warranty Info
    3 Year Warranty

Reviews (1)

Keep your team protected & compliant!

  • Expert guidance tailored to your specific needs
  • Access responsive customer support when you need it
  • Enjoy fast shipping directly to your location
  • Benefit from extensive industry knowledge—75+ years of experience
  • In-house gas detection calibration & repair services available
The RKI Instruments OX-04 Series O2 Single Gas Monitor (72-0018) displays "20.9%" for oxygen on its green screen, features "AIR" and "POWER MODE" buttons, and is clearly marked with the RKI Instruments brand.
RKI Instruments

RKI Instruments OX-04 Series O2 Single Gas Monitor 72-0018

$118.00

RKI Instruments OX-04 Series O2 Single Gas Monitor is a single-gas toxic personal monitor designed to operate for many years with field replaceable sensors and filters.

With a protective rubber boot and an IP-67 rating, the 04 Series with a 3 year warranty is built to operate for a long time.

Applications: Hazardous material, Mining, Refineries / petrochemical, Water / wastewater treatment, Pharmaceuticals, Utilities, Chemical plants, Fire Services

Key Features:

Specifications:

Monitor Includes:

Optional Accessory: Downloading cable, USB / IrDA adapter

Specification Sheet:

Specification Sheet

04 Series User Setup Program Operator’s Manual:

04 Series User Setup Program Operator’s Manual

04 Series Data Logger Management Program Operator’s Manual:

04 Series Data Logger Management Program Operator’s Manual

Part Number:
72-0018

Frequently Asked Questions

What oxygen levels trigger alarms on the RKI OX-04 monitor?

The OX-04 ships with three alarm setpoints: L alarm at 19.5% O2, LL alarm at 18.0% O2, and an H alarm at 23.5% O2 for oxygen-enriched atmospheres. OSHA 29 CFR 1910.146 defines an oxygen-deficient atmosphere as any space with less than 19.5% O2 by volume — requiring permit-required confined space protocols. All setpoints are user-adjustable to align with your site safety program.

How long do alkaline batteries last in the OX-04 Series O2 monitor?

The OX-04 operates approximately 3,000 hours on a set of two AAA alkaline batteries — over four months of continuous use. The continuous operating ceiling is rated at 4,600 hours. The low battery alarm activates before the instrument reaches an unsafe operating voltage, giving workers time to replace batteries without gaps in monitoring coverage.

What applications require continuous personal oxygen monitoring?

O2 monitoring is required wherever inert gas purging, liquid nitrogen use, cryogenic processes, or incomplete combustion can displace oxygen. Common applications include laboratories, confined space entry under 29 CFR 1910.146, cryogenic environments, industrial gas storage rooms, clean rooms, and underground utility vaults. See PK Safety’s portable gas monitors collection for multi-gas options that pair O2 detection with LEL, CO, and H2S.

Does PK Safety service and calibrate RKI OX-04 monitors in-house?

PK Safety services RKI instruments in-house with factory-trained technicians, providing NIST-traceable oxygen calibration, sensor replacement, and data log retrieval for the OX-04 Series. The 04 Series warranty — 3 years including sensors — is supported through PK Safety’s service center. Call 800.829.9580 to schedule calibration or inquire about service pricing.

What intrinsic safety approval does the OX-04 Series carry?

The OX-04 is ATEX/IECEx approved and QPS classified C/US as intrinsically safe for Class I, Division 1, Groups A, B, C, D locations. Intrinsic safety certification confirms the monitor cannot produce sufficient electrical energy to ignite a flammable atmosphere, making it compliant for classified areas such as chemical plants, refineries, and petrochemical facilities. Always verify the certification label on your specific unit before deploying in classified zones.

How does the electrochemical sensor in the OX-04 detect oxygen?

Electrochemical oxygen sensors generate a small electrical current proportional to the partial pressure of oxygen diffusing through a membrane into an electrolyte solution. The sensor requires no external power to produce its signal, and the OX-04’s electrochemical cell is field-replaceable with no tools required, keeping maintenance straightforward. Response time is T90 in 10 seconds.

Related Searches
Gas Detection, O2 Gas Monitors, Portable Gas Monitors And Detectors, Rki Instruments, Single-Gas Monitors

View product