Expert Guidance Monday-Friday, 6:30am-4pm PST. Call Now! Request a Quote Click Here!

SKU: RKI01-72-0038

RKI 03 Series LEL Single Gas Monitor with NI-MH Battery 72-0038

$393.08

Ships in 3 - 4 days

Description

RKI Instruments 03 Series LEL Single Gas Monitor is designed for protection from exposure to combustible hydrocarbons. The GP-03 operates for 35 hours on alkaline and 30 hours on rechargeable Ni-MH. The 03 models have 2 preset alarms that are user adjustable. Each version is also equipped with visual, audible, and vibration alarms as standard. The RKI 03 Series Monitors are great in areas of hazardous material, mining, tunnels, refineries or petrochemical, water and wastewater treatment, pharmaceuticals, utilities, chemical plants and fire services.

Applications: Hazardous material, Mining, Refineries/petrochemical, Water/wastewater treatment, Pharmaceuticals, Utilities, Chemical plants, Fire services

Key Features:

  • Pocket size 2.1 in. (W) x 2.6 in. (H) x 0.9 in. (D)
  • Lightweight (2.8 oz.)
  • Impact, dust, and water resistant (IP-67)
  • Replaceable rubber boot
  • Data log from 5 to 300 hours with adjustable intervals
  • Audible / visual / vibration alarms
  • Automatic backlight
  • Low battery alarm

Specifications:

  • Combustible gas
  • Detection principle: Catalytic combustion
  • Detection range: 0 - 100 percent LEL
  • Alarm set points: 1st - 10 percent LEL, 2nd - 50 percent LEL, Over - 100 percent LEL
  • Alarm types: Gas alarms: 1st and 2nd (user adjustable), OVER alarm, STEL and TWA; Trouble alarms: Sensor connection, low battery, circuit failure, and calibration range error
  • Gas sampling: Diffusion
  • Response time: T90 in 30 seconds
  • Accuracy: 0.5 percent of reading or ±2 ppm LEL
  • Data logging: 10 second intervals = 5 hours, 5 minute intervals = 150 hours, 10 minute intervals = 300 hours. Instrument records alarms, alarm trends, gas readings, calibration & bump test history, instrument information and settings
  • Safety rating: ATEX/IECEx approved. CSA classified, C/US, as intrinsically safe, Class I, Division 1, Groups A, B, C, D (pending)
  • Enclosure: Dust and water resistant with IP-67 rating
  • Display: Digital LCD, gas name & concentration, auto backlighting during alarm, operation icon, battery icon
  • 2 year warranty

Monitor Includes:

  • Rubber protective boot
  • Alkaline batteries
  • Alligator clip
  • Wrist strap
  • Data log software

Please Note: Once activated, these units cannot be shut down and will continue to run for their life span prohibiting these items from being shipped because the alarm may be activated during transit. Additionally, these items are unable to be resold after activation. Of course, if you haven't yet activated your monitor, we will happily take it back.

Optional Accessory: Downloading cable, USB / IrDA adapter

Part Numbers:
72-0038 - Monitor only
72-0038-01 - LEL-03 Monitor with charger


Frequently Asked Questions

What gases does the RKI 03 Series LEL monitor detect?

The 03 Series uses catalytic combustion sensing to detect combustible hydrocarbons in the 0–100% LEL range. It is calibrated for methane (CH4) and responds to a wide range of flammable vapors including propane, butane, and other hydrocarbons. For questions about a specific target gas, contact PK Safety at 800.829.9580.

What is the runtime difference between the NI-MH and alkaline versions?

The 72-0038 includes a NI-MH rechargeable pack and runs approximately 30 hours per charge. The alkaline variant (72-0037) delivers approximately 35 hours per set of batteries. The rechargeable option lowers long-term consumable costs in facilities where the monitor is used daily and a charging station is available.

At what LEL percentage do the alarms activate on the 03 Series monitor?

Factory defaults: first alarm at 10% LEL, second alarm at 50% LEL, OVER alarm at 100% LEL. Both user-adjustable setpoints let safety managers align the instrument to their site program. OSHA 29 CFR 1910.146 requires employers to evaluate and control flammable atmospheric hazards in permit-required confined spaces — many programs set action levels at or below 10% LEL.

Does PK Safety service and calibrate RKI 03 Series monitors?

PK Safety services RKI instruments in-house with factory-trained technicians, covering calibration, bump testing, sensor replacement, and repair for the full RKI portable line including the 03 Series. Calibration is recommended every 6 months or per your site safety program. Call our gas detection team at 800.829.9580 to schedule service or order calibration gas.

What does IP-67 protection mean for the 03 Series monitor in the field?

IP-67 indicates the monitor is fully dust-tight (rating 6) and can survive temporary immersion in up to 1 meter of water for 30 minutes (rating 7). This makes it suitable for wet industrial environments — water and wastewater plants, outdoor petrochemical sites, and construction — without requiring an additional protective housing.

What intrinsic safety certifications does the 72-0038 carry?

The 72-0038 carries ATEX/IECEx approval and CSA classification C/US as intrinsically safe for Class I, Division 1, Groups A, B, C, D hazardous locations (CSA pending at time of publication). These certifications confirm the monitor will not ignite flammable atmospheres under normal or single-fault conditions. Always verify the certification label on your specific unit before deploying in classified areas.

Related Searches
Gas Detection, Lel Gas Monitors, Portable Gas Monitors And Detectors, Rki Instruments, Single-Gas Monitors

Read more

RKI Instruments 03 Series LEL Single Gas Monitor is designed for protection from exposure to combustible hydrocarbons. The GP-03 operates for 35 hours on alkaline and 30 hours on rechargeable Ni-MH. The 03 models have 2 preset alarms that are user adjustable. Each version is also equipped with visual, audible, and vibration alarms as standard. The RKI 03 Series Monitors are great in areas of hazardous material, mining, tunnels, refineries or petrochemical, water and wastewater treatment, pharmaceuticals, utilities, chemical plants and fire services.

Applications: Hazardous material, Mining, Refineries/petrochemical, Water/wastewater treatment, Pharmaceuticals, Utilities, Chemical plants, Fire services

Key Features:

  • Pocket size 2.1 in. (W) x 2.6 in. (H) x 0.9 in. (D)
  • Lightweight (2.8 oz.)
  • Impact, dust, and water resistant (IP-67)
  • Replaceable rubber boot
  • Data log from 5 to 300 hours with adjustable intervals
  • Audible / visual / vibration alarms
  • Automatic backlight
  • Low battery alarm

Specifications:

  • Combustible gas
  • Detection principle: Catalytic combustion
  • Detection range: 0 - 100 percent LEL
  • Alarm set points: 1st - 10 percent LEL, 2nd - 50 percent LEL, Over - 100 percent LEL
  • Alarm types: Gas alarms: 1st and 2nd (user adjustable), OVER alarm, STEL and TWA; Trouble alarms: Sensor connection, low battery, circuit failure, and calibration range error
  • Gas sampling: Diffusion
  • Response time: T90 in 30 seconds
  • Accuracy: 0.5 percent of reading or ±2 ppm LEL
  • Data logging: 10 second intervals = 5 hours, 5 minute intervals = 150 hours, 10 minute intervals = 300 hours. Instrument records alarms, alarm trends, gas readings, calibration & bump test history, instrument information and settings
  • Safety rating: ATEX/IECEx approved. CSA classified, C/US, as intrinsically safe, Class I, Division 1, Groups A, B, C, D (pending)
  • Enclosure: Dust and water resistant with IP-67 rating
  • Display: Digital LCD, gas name & concentration, auto backlighting during alarm, operation icon, battery icon
  • 2 year warranty

Monitor Includes:

  • Rubber protective boot
  • Alkaline batteries
  • Alligator clip
  • Wrist strap
  • Data log software

Please Note: Once activated, these units cannot be shut down and will continue to run for their life span prohibiting these items from being shipped because the alarm may be activated during transit. Additionally, these items are unable to be resold after activation. Of course, if you haven't yet activated your monitor, we will happily take it back.

Optional Accessory: Downloading cable, USB / IrDA adapter

Part Numbers:
72-0038 - Monitor only
72-0038-01 - LEL-03 Monitor with charger


Frequently Asked Questions

What gases does the RKI 03 Series LEL monitor detect?

The 03 Series uses catalytic combustion sensing to detect combustible hydrocarbons in the 0–100% LEL range. It is calibrated for methane (CH4) and responds to a wide range of flammable vapors including propane, butane, and other hydrocarbons. For questions about a specific target gas, contact PK Safety at 800.829.9580.

What is the runtime difference between the NI-MH and alkaline versions?

The 72-0038 includes a NI-MH rechargeable pack and runs approximately 30 hours per charge. The alkaline variant (72-0037) delivers approximately 35 hours per set of batteries. The rechargeable option lowers long-term consumable costs in facilities where the monitor is used daily and a charging station is available.

At what LEL percentage do the alarms activate on the 03 Series monitor?

Factory defaults: first alarm at 10% LEL, second alarm at 50% LEL, OVER alarm at 100% LEL. Both user-adjustable setpoints let safety managers align the instrument to their site program. OSHA 29 CFR 1910.146 requires employers to evaluate and control flammable atmospheric hazards in permit-required confined spaces — many programs set action levels at or below 10% LEL.

Does PK Safety service and calibrate RKI 03 Series monitors?

PK Safety services RKI instruments in-house with factory-trained technicians, covering calibration, bump testing, sensor replacement, and repair for the full RKI portable line including the 03 Series. Calibration is recommended every 6 months or per your site safety program. Call our gas detection team at 800.829.9580 to schedule service or order calibration gas.

What does IP-67 protection mean for the 03 Series monitor in the field?

IP-67 indicates the monitor is fully dust-tight (rating 6) and can survive temporary immersion in up to 1 meter of water for 30 minutes (rating 7). This makes it suitable for wet industrial environments — water and wastewater plants, outdoor petrochemical sites, and construction — without requiring an additional protective housing.

What intrinsic safety certifications does the 72-0038 carry?

The 72-0038 carries ATEX/IECEx approval and CSA classification C/US as intrinsically safe for Class I, Division 1, Groups A, B, C, D hazardous locations (CSA pending at time of publication). These certifications confirm the monitor will not ignite flammable atmospheres under normal or single-fault conditions. Always verify the certification label on your specific unit before deploying in classified areas.

Related Searches
Gas Detection, Lel Gas Monitors, Portable Gas Monitors And Detectors, Rki Instruments, Single-Gas Monitors

Specifications

  • Gas Type
    LEL
  • Color
    Black
  • Height (in.)
    1
  • Length (in.)
    12
  • Width (in.)
    8.5
  • Country of Origin
    JP
  • Warranty Info
    2 Year Warranty

Reviews

Keep your team protected & compliant!

  • Expert guidance tailored to your specific needs
  • Access responsive customer support when you need it
  • Enjoy fast shipping directly to your location
  • Benefit from extensive industry knowledge—75+ years of experience
  • In-house gas detection calibration & repair services available
A black RKI Instruments 03 Series LEL Single Gas Monitor, featuring a digital display indicates "CH4 0% LEL." It is equipped with two buttons labeled "AIR" and "POWER MODE" for monitoring combustible hydrocarbons. The device prominently displays a yellow "LEL" label and the brand name "RKI Instruments GP-03.
RKI Instruments

RKI 03 Series LEL Single Gas Monitor with NI-MH Battery 72-0038

From $393.08

RKI Instruments 03 Series LEL Single Gas Monitor is designed for protection from exposure to combustible hydrocarbons. The GP-03 operates for 35 hours on alkaline and 30 hours on rechargeable Ni-MH. The 03 models have 2 preset alarms that are user adjustable. Each version is also equipped with visual, audible, and vibration alarms as standard. The RKI 03 Series Monitors are great in areas of hazardous material, mining, tunnels, refineries or petrochemical, water and wastewater treatment, pharmaceuticals, utilities, chemical plants and fire services.

Applications: Hazardous material, Mining, Refineries/petrochemical, Water/wastewater treatment, Pharmaceuticals, Utilities, Chemical plants, Fire services

Key Features:

Specifications:

Monitor Includes:

Please Note: Once activated, these units cannot be shut down and will continue to run for their life span prohibiting these items from being shipped because the alarm may be activated during transit. Additionally, these items are unable to be resold after activation. Of course, if you haven't yet activated your monitor, we will happily take it back.

Optional Accessory: Downloading cable, USB / IrDA adapter

Part Numbers:
72-0038 - Monitor only
72-0038-01 - LEL-03 Monitor with charger


Frequently Asked Questions

What gases does the RKI 03 Series LEL monitor detect?

The 03 Series uses catalytic combustion sensing to detect combustible hydrocarbons in the 0–100% LEL range. It is calibrated for methane (CH4) and responds to a wide range of flammable vapors including propane, butane, and other hydrocarbons. For questions about a specific target gas, contact PK Safety at 800.829.9580.

What is the runtime difference between the NI-MH and alkaline versions?

The 72-0038 includes a NI-MH rechargeable pack and runs approximately 30 hours per charge. The alkaline variant (72-0037) delivers approximately 35 hours per set of batteries. The rechargeable option lowers long-term consumable costs in facilities where the monitor is used daily and a charging station is available.

At what LEL percentage do the alarms activate on the 03 Series monitor?

Factory defaults: first alarm at 10% LEL, second alarm at 50% LEL, OVER alarm at 100% LEL. Both user-adjustable setpoints let safety managers align the instrument to their site program. OSHA 29 CFR 1910.146 requires employers to evaluate and control flammable atmospheric hazards in permit-required confined spaces — many programs set action levels at or below 10% LEL.

Does PK Safety service and calibrate RKI 03 Series monitors?

PK Safety services RKI instruments in-house with factory-trained technicians, covering calibration, bump testing, sensor replacement, and repair for the full RKI portable line including the 03 Series. Calibration is recommended every 6 months or per your site safety program. Call our gas detection team at 800.829.9580 to schedule service or order calibration gas.

What does IP-67 protection mean for the 03 Series monitor in the field?

IP-67 indicates the monitor is fully dust-tight (rating 6) and can survive temporary immersion in up to 1 meter of water for 30 minutes (rating 7). This makes it suitable for wet industrial environments — water and wastewater plants, outdoor petrochemical sites, and construction — without requiring an additional protective housing.

What intrinsic safety certifications does the 72-0038 carry?

The 72-0038 carries ATEX/IECEx approval and CSA classification C/US as intrinsically safe for Class I, Division 1, Groups A, B, C, D hazardous locations (CSA pending at time of publication). These certifications confirm the monitor will not ignite flammable atmospheres under normal or single-fault conditions. Always verify the certification label on your specific unit before deploying in classified areas.

Related Searches
Gas Detection, Lel Gas Monitors, Portable Gas Monitors And Detectors, Rki Instruments, Single-Gas Monitors

Configuration

  • Monitor only
  • Add Charger
View product