Description
The RAE Systems ToxiRAE Pro H2S (G02-B110-100) is a personal single-gas detector for hydrogen sulfide — the number-one atmospheric killer in oil & gas, wastewater, and confined-space work. Compact enough to clip to a lapel or hard hat, intrinsically safe for Class I Division 1, with on-board data logging, Man Down alarm, and five-way wireless alarm notification, it is the workhorse H2S monitor for upstream wellsite work, sour-gas refining, lift stations, and tannery environments. Compare the full RAE Systems ToxiRAE Pro single-gas family — H2S, CO, HCN, NH3, and LEL — or step up to a multi-gas MultiRAE.
Specifications
- Target gas: Hydrogen Sulfide (H2S)
- Range: 0 to 100 ppm
- Resolution: 0.1 ppm
- Largest display in class; graphical LCD with white LED backlight
- Water-, dust-, and shock-resistant housing; concussion-proof rubber boot
- Intelligent sensors store calibration data even when swapped between hosts
- Five-way local and remote alarms: audible, visual, vibratory
- Man Down alarm with real-time remote wireless notification
- Continuous data logging with 3-month capacity at 1-minute intervals; user-configurable interval 1 to 3,600 seconds
- Rechargeable Li-ion battery; operating time >30 hours (non-wireless); recharge <4 hours through charging cradle
- Operating temperature -4° to 131°F; 0 to 95% RH non-condensing
- Intrinsic-safety certifications: CSA Class I Division 1 Groups A, B, C, D (T4); Class I Zone 0 AEx ia IIC T4; ATEX II 1G Ex ia IIC Ga T4; IECEx Ex ia IIC Ga T4
- Easy to maintain — replaceable sensor, filter, and Li-ion battery
Applications
- Oil & gas upstream, midstream, and sour-gas refining
- Wastewater treatment, lift stations, and sewer entry
- Pulp & paper (Kraft pulping)
- Tanneries and leather processing
- Confined-space entry and permit-required work
- Agriculture (manure handling, biogas)
Compatibility and Service
PK Safety is a RAE Systems Factory Authorized Service Center. Our in-house RAE technicians calibrate, bump test, and repair the ToxiRAE Pro H2S at our Alameda, California service lab. We also service BW Technologies by Honeywell, RKI Instruments, and WatchGas monitors — a mixed fleet can be sent in one shipment. Call 800.829.9580 for sensor-configuration questions, service scheduling, or sizing help.
Part Number: G02-B110-100
Frequently Asked Questions
What does the ToxiRAE Pro H2S detect, and what does it not?
The ToxiRAE Pro H2S is a single-gas detector dedicated to Hydrogen Sulfide across 0 to 100 ppm at 0.1 ppm resolution. It is not a multi-gas instrument — for simultaneous LEL, O2, CO, and H2S confined-space monitoring, use a MultiRAE or QRAE 3 instead.
Is the ToxiRAE Pro intrinsically safe for Class I Division 1?
Yes. The ToxiRAE Pro H2S carries CSA Class I Division 1 Groups A, B, C, D (T4); Class I Zone 0 AEx ia IIC T4; ATEX II 1G Ex ia IIC Ga T4; IECEx Ex ia IIC Ga T4. Confirm the specific marking on the instrument label matches your area classification before entry; call 800.829.9580 if you need the current approval sheet for a permit submittal.
How often should the ToxiRAE Pro H2S be bump tested and calibrated?
Follow OSHA Safety and Health Information Bulletin SHIB 09-30-13, which calls for a functional bump test with a known concentration of target gas before each day's use on any portable gas monitor and a full calibration whenever a bump test fails, after a sensor change, or on RAE's recommended 180-day interval. Span gas is typically 25 ppm H2S in a 34L cylinder with a RAE fixed-flow regulator. The AutoRAE 2 docking station automates both bump and calibration for a fleet.
What alarms will the ToxiRAE Pro trigger?
Five-way local and remote notification: audible (95 dB at 30 cm), bright visual LEDs, and vibratory alarm, with Man Down activation if the instrument stops moving for a configurable interval. Wireless models (when paired with the EchoView Host) also push the alarm status to a remote safety officer.
What accessories pair with the ToxiRAE Pro?
The ToxiRAE Pro ships with an alligator clip, rubber boot, charging/PC cradle, PC cable, AC adapter, and calibration adapter. Replacement H2S sensors, Li-ion batteries, filters, and the AutoRAE 2 docking station are stocked under Gas Detector Accessories; span gas is under Calibration Gas.
Who services the ToxiRAE Pro H2S when it fails?
PK Safety is a RAE Systems Factory Authorized Service Center. Our in-house RAE technicians swap sensors and batteries, update firmware, and run full calibration from our Alameda, California shop. Call 800.829.9580 to open a service ticket.
Related Searches
RAE Systems, Gas Detection, Single-Gas Monitors, Calibration Gas, Gas Detector Accessories
Read more
Description
The RAE Systems ToxiRAE Pro H2S (G02-B110-100) is a personal single-gas detector for hydrogen sulfide — the number-one atmospheric killer in oil & gas, wastewater, and confined-space work. Compact enough to clip to a lapel or hard hat, intrinsically safe for Class I Division 1, with on-board data logging, Man Down alarm, and five-way wireless alarm notification, it is the workhorse H2S monitor for upstream wellsite work, sour-gas refining, lift stations, and tannery environments. Compare the full RAE Systems ToxiRAE Pro single-gas family — H2S, CO, HCN, NH3, and LEL — or step up to a multi-gas MultiRAE.
Specifications
- Target gas: Hydrogen Sulfide (H2S)
- Range: 0 to 100 ppm
- Resolution: 0.1 ppm
- Largest display in class; graphical LCD with white LED backlight
- Water-, dust-, and shock-resistant housing; concussion-proof rubber boot
- Intelligent sensors store calibration data even when swapped between hosts
- Five-way local and remote alarms: audible, visual, vibratory
- Man Down alarm with real-time remote wireless notification
- Continuous data logging with 3-month capacity at 1-minute intervals; user-configurable interval 1 to 3,600 seconds
- Rechargeable Li-ion battery; operating time >30 hours (non-wireless); recharge <4 hours through charging cradle
- Operating temperature -4° to 131°F; 0 to 95% RH non-condensing
- Intrinsic-safety certifications: CSA Class I Division 1 Groups A, B, C, D (T4); Class I Zone 0 AEx ia IIC T4; ATEX II 1G Ex ia IIC Ga T4; IECEx Ex ia IIC Ga T4
- Easy to maintain — replaceable sensor, filter, and Li-ion battery
Applications
- Oil & gas upstream, midstream, and sour-gas refining
- Wastewater treatment, lift stations, and sewer entry
- Pulp & paper (Kraft pulping)
- Tanneries and leather processing
- Confined-space entry and permit-required work
- Agriculture (manure handling, biogas)
Compatibility and Service
PK Safety is a RAE Systems Factory Authorized Service Center. Our in-house RAE technicians calibrate, bump test, and repair the ToxiRAE Pro H2S at our Alameda, California service lab. We also service BW Technologies by Honeywell, RKI Instruments, and WatchGas monitors — a mixed fleet can be sent in one shipment. Call 800.829.9580 for sensor-configuration questions, service scheduling, or sizing help.
Part Number: G02-B110-100
Frequently Asked Questions
What does the ToxiRAE Pro H2S detect, and what does it not?
The ToxiRAE Pro H2S is a single-gas detector dedicated to Hydrogen Sulfide across 0 to 100 ppm at 0.1 ppm resolution. It is not a multi-gas instrument — for simultaneous LEL, O2, CO, and H2S confined-space monitoring, use a MultiRAE or QRAE 3 instead.
Is the ToxiRAE Pro intrinsically safe for Class I Division 1?
Yes. The ToxiRAE Pro H2S carries CSA Class I Division 1 Groups A, B, C, D (T4); Class I Zone 0 AEx ia IIC T4; ATEX II 1G Ex ia IIC Ga T4; IECEx Ex ia IIC Ga T4. Confirm the specific marking on the instrument label matches your area classification before entry; call 800.829.9580 if you need the current approval sheet for a permit submittal.
How often should the ToxiRAE Pro H2S be bump tested and calibrated?
Follow OSHA Safety and Health Information Bulletin SHIB 09-30-13, which calls for a functional bump test with a known concentration of target gas before each day's use on any portable gas monitor and a full calibration whenever a bump test fails, after a sensor change, or on RAE's recommended 180-day interval. Span gas is typically 25 ppm H2S in a 34L cylinder with a RAE fixed-flow regulator. The AutoRAE 2 docking station automates both bump and calibration for a fleet.
What alarms will the ToxiRAE Pro trigger?
Five-way local and remote notification: audible (95 dB at 30 cm), bright visual LEDs, and vibratory alarm, with Man Down activation if the instrument stops moving for a configurable interval. Wireless models (when paired with the EchoView Host) also push the alarm status to a remote safety officer.
What accessories pair with the ToxiRAE Pro?
The ToxiRAE Pro ships with an alligator clip, rubber boot, charging/PC cradle, PC cable, AC adapter, and calibration adapter. Replacement H2S sensors, Li-ion batteries, filters, and the AutoRAE 2 docking station are stocked under Gas Detector Accessories; span gas is under Calibration Gas.
Who services the ToxiRAE Pro H2S when it fails?
PK Safety is a RAE Systems Factory Authorized Service Center. Our in-house RAE technicians swap sensors and batteries, update firmware, and run full calibration from our Alameda, California shop. Call 800.829.9580 to open a service ticket.
Related Searches
RAE Systems, Gas Detection, Single-Gas Monitors, Calibration Gas, Gas Detector Accessories
The RAE Systems ToxiRAE Pro H2S (G02-B110-100) is a personal single-gas detector for hydrogen sulfide — the number-one atmospheric killer in oil & gas, wastewater, and confined-space work. Compact enough to clip to a lapel or hard hat, intrinsically safe for Class I Division 1, with on-board data logging, Man Down alarm, and five-way wireless alarm notification, it is the workhorse H2S monitor for upstream wellsite work, sour-gas refining, lift stations, and tannery environments. Compare the full RAE Systems ToxiRAE Pro single-gas family — H2S, CO, HCN, NH3, and LEL — or step up to a multi-gas MultiRAE.
Specifications
- Target gas: Hydrogen Sulfide (H2S)
- Range: 0 to 100 ppm
- Resolution: 0.1 ppm
- Largest display in class; graphical LCD with white LED backlight
- Water-, dust-, and shock-resistant housing; concussion-proof rubber boot
- Intelligent sensors store calibration data even when swapped between hosts
- Five-way local and remote alarms: audible, visual, vibratory
- Man Down alarm with real-time remote wireless notification
- Continuous data logging with 3-month capacity at 1-minute intervals; user-configurable interval 1 to 3,600 seconds
- Rechargeable Li-ion battery; operating time >30 hours (non-wireless); recharge <4 hours through charging cradle
- Operating temperature -4° to 131°F; 0 to 95% RH non-condensing
- Intrinsic-safety certifications: CSA Class I Division 1 Groups A, B, C, D (T4); Class I Zone 0 AEx ia IIC T4; ATEX II 1G Ex ia IIC Ga T4; IECEx Ex ia IIC Ga T4
- Easy to maintain — replaceable sensor, filter, and Li-ion battery
Applications
- Oil & gas upstream, midstream, and sour-gas refining
- Wastewater treatment, lift stations, and sewer entry
- Pulp & paper (Kraft pulping)
- Tanneries and leather processing
- Confined-space entry and permit-required work
- Agriculture (manure handling, biogas)
Compatibility and Service
PK Safety is a RAE Systems Factory Authorized Service Center. Our in-house RAE technicians calibrate, bump test, and repair the ToxiRAE Pro H2S at our Alameda, California service lab. We also service BW Technologies by Honeywell, RKI Instruments, and WatchGas monitors — a mixed fleet can be sent in one shipment. Call 800.829.9580 for sensor-configuration questions, service scheduling, or sizing help.
Part Number: G02-B110-100
Frequently Asked Questions
What does the ToxiRAE Pro H2S detect, and what does it not?
The ToxiRAE Pro H2S is a single-gas detector dedicated to Hydrogen Sulfide across 0 to 100 ppm at 0.1 ppm resolution. It is not a multi-gas instrument — for simultaneous LEL, O2, CO, and H2S confined-space monitoring, use a MultiRAE or QRAE 3 instead.
Is the ToxiRAE Pro intrinsically safe for Class I Division 1?
Yes. The ToxiRAE Pro H2S carries CSA Class I Division 1 Groups A, B, C, D (T4); Class I Zone 0 AEx ia IIC T4; ATEX II 1G Ex ia IIC Ga T4; IECEx Ex ia IIC Ga T4. Confirm the specific marking on the instrument label matches your area classification before entry; call 800.829.9580 if you need the current approval sheet for a permit submittal.
How often should the ToxiRAE Pro H2S be bump tested and calibrated?
Follow OSHA Safety and Health Information Bulletin SHIB 09-30-13, which calls for a functional bump test with a known concentration of target gas before each day's use on any portable gas monitor and a full calibration whenever a bump test fails, after a sensor change, or on RAE's recommended 180-day interval. Span gas is typically 25 ppm H2S in a 34L cylinder with a RAE fixed-flow regulator. The AutoRAE 2 docking station automates both bump and calibration for a fleet.
What alarms will the ToxiRAE Pro trigger?
Five-way local and remote notification: audible (95 dB at 30 cm), bright visual LEDs, and vibratory alarm, with Man Down activation if the instrument stops moving for a configurable interval. Wireless models (when paired with the EchoView Host) also push the alarm status to a remote safety officer.
What accessories pair with the ToxiRAE Pro?
The ToxiRAE Pro ships with an alligator clip, rubber boot, charging/PC cradle, PC cable, AC adapter, and calibration adapter. Replacement H2S sensors, Li-ion batteries, filters, and the AutoRAE 2 docking station are stocked under Gas Detector Accessories; span gas is under Calibration Gas.
Who services the ToxiRAE Pro H2S when it fails?
PK Safety is a RAE Systems Factory Authorized Service Center. Our in-house RAE technicians swap sensors and batteries, update firmware, and run full calibration from our Alameda, California shop. Call 800.829.9580 to open a service ticket.
Related Searches
RAE Systems, Gas Detection, Single-Gas Monitors, Calibration Gas, Gas Detector Accessories
Specifications
Specifications
-
Type
-
Gas Type
-
Height (in.)
-
Length (in.)
-
Width (in.)
-
Country of Origin
Reviews
Reviews
Keep your team protected & compliant!
- Expert guidance tailored to your specific needs
- Access responsive customer support when you need it
- Enjoy fast shipping directly to your location
- Benefit from extensive industry knowledge—75+ years of experience
- In-house gas detection calibration & repair services available