Expert Guidance Monday-Friday, 6:30am-4pm PST. Call Now! Request a Quote Click Here!

SKU: RKI01-72-2104A-01

RKI Beacon 410A Four Channel Wall Mount Controller 72-2104A

$3,478.85

Ships in 6 - 8 weeks

Description

RKI Beacon 410A Four Channel Wall Mount Controller is a highly configurable, microprocessor-based 4-channel gas monitoring controller. It simultaneously displays the gas type, readings, and status for four channels of gas detection and can monitor any combination of Direct Connect sensors (LEL, O2, CO2, and toxic gas sensors) as well as any 4-20 mA transmitter.

Each channel supports up to three fully configurable alarm points with two dedicated alarm relays. A bank of common relays can optionally provide up to 3 alarm relays per channel. A silenceable audible alarm, 4-20 mA analog output, and Modbus digital output are standard. A Min-Max feature retains peak readings for review at any time. All features are controlled through easy-to-navigate menus on the built-in OLED display—no laptop or external programming device required for basic configuration.

The unit operates from 115/220 VAC or 24 VDC, with an optional trickle-charging battery backup. An optional high-visibility strobe is available. The NEMA 4X enclosure resists weather and corrosion. Made in the USA.

Applications: Petrochemical plants, Refineries, Water & wastewater treatment plants, Pulp & paper mills, Gas, telephone & electric utilities, Parking garages, Manufacturing facilities, Steel, Automotive, HVAC

Key Features:

  • Simultaneously controls up to 4 gas monitoring channels
  • OLED display of all 4 channels
  • LEL / O2 / CO2 / toxic Direct Connect sensor support
  • Accepts any 4-20 mA transmitter (2 or 3 wire)
  • Up to 3 programmable alarm levels per channel
  • Up to 3 configurable alarm relays per channel
  • 4-20 mA analog & Modbus digital output standard
  • 115/220 VAC or 24 VDC operation
  • Audible alarm with silence feature
  • RFI/EMI resistant
  • Alarm reset switch
  • Built-in trouble alarm with relay
  • Weather and corrosion resistant NEMA 4X enclosure
  • Made in the USA

Specification Sheet:

Specification Sheet

Manual:

Manual

Part Numbers:
72-2104A - Beacon 410A, four channel controller (no sensor)
72-2104A-01 - Beacon 410A, four channel controller with battery charger (no sensors or back-up battery)
72-2104A-13R - Beacon 410A, four channel controller with large red strobe light (no sensor)
72-2104A-14R - Beacon 410A, four channel controller with battery charger terminals and large red strobe light (no sensors or back-up battery)

Related Searches
Controllers, Fixed Gas Detectors, Gas Detection, RKI Instruments

Frequently Asked Questions

How many gas monitoring channels does the Beacon 410A support?

The Beacon 410A supports up to four gas monitoring channels simultaneously. Each channel can be independently configured for a different gas type, alarm setpoint, and relay behavior, making it suitable for facilities that need to monitor multiple hazardous gases across different locations from a single wall-mount controller.

Does the Beacon 410A require add-on expansion cards?

No. All relays, 4-20 mA analog outputs, and Modbus digital outputs are built into the Beacon 410A as standard features. There are no add-on cards, optional modules, or additional firmware licenses to purchase—everything is included in the base unit.

What power supply options are available for the Beacon 410A?

The Beacon 410A operates from 115/220 VAC or an external 24 VDC source. An optional trickle-charging battery backup is available for the -01 and -14R variants, providing continued operation during power outages.

What sensors work with the Beacon 410A?

The Beacon 410A accepts any combination of RKI Direct Connect sensors (LEL, O2, CO2, and toxic gas variants) and any industry-standard 4-20 mA transmitter in 2-wire or 3-wire configuration. This makes the controller compatible with the full RKI sensor ecosystem as well as many third-party field transmitters.

How is the Beacon 410A configured?

All settings—alarm setpoints, relay assignments, channel type, min/max recording, and optional strobe control—are managed through the built-in OLED display using a straightforward menu system. No laptop, programming cable, or proprietary software is required for standard configuration. Contact PK Safety at 800.829.9580 if engineering support is needed for complex installations.

Read more

RKI Beacon 410A Four Channel Wall Mount Controller is a highly configurable, microprocessor-based 4-channel gas monitoring controller. It simultaneously displays the gas type, readings, and status for four channels of gas detection and can monitor any combination of Direct Connect sensors (LEL, O2, CO2, and toxic gas sensors) as well as any 4-20 mA transmitter.

Each channel supports up to three fully configurable alarm points with two dedicated alarm relays. A bank of common relays can optionally provide up to 3 alarm relays per channel. A silenceable audible alarm, 4-20 mA analog output, and Modbus digital output are standard. A Min-Max feature retains peak readings for review at any time. All features are controlled through easy-to-navigate menus on the built-in OLED display—no laptop or external programming device required for basic configuration.

The unit operates from 115/220 VAC or 24 VDC, with an optional trickle-charging battery backup. An optional high-visibility strobe is available. The NEMA 4X enclosure resists weather and corrosion. Made in the USA.

Applications: Petrochemical plants, Refineries, Water & wastewater treatment plants, Pulp & paper mills, Gas, telephone & electric utilities, Parking garages, Manufacturing facilities, Steel, Automotive, HVAC

Key Features:

  • Simultaneously controls up to 4 gas monitoring channels
  • OLED display of all 4 channels
  • LEL / O2 / CO2 / toxic Direct Connect sensor support
  • Accepts any 4-20 mA transmitter (2 or 3 wire)
  • Up to 3 programmable alarm levels per channel
  • Up to 3 configurable alarm relays per channel
  • 4-20 mA analog & Modbus digital output standard
  • 115/220 VAC or 24 VDC operation
  • Audible alarm with silence feature
  • RFI/EMI resistant
  • Alarm reset switch
  • Built-in trouble alarm with relay
  • Weather and corrosion resistant NEMA 4X enclosure
  • Made in the USA

Specification Sheet:

Specification Sheet

Manual:

Manual

Part Numbers:
72-2104A - Beacon 410A, four channel controller (no sensor)
72-2104A-01 - Beacon 410A, four channel controller with battery charger (no sensors or back-up battery)
72-2104A-13R - Beacon 410A, four channel controller with large red strobe light (no sensor)
72-2104A-14R - Beacon 410A, four channel controller with battery charger terminals and large red strobe light (no sensors or back-up battery)

Related Searches
Controllers, Fixed Gas Detectors, Gas Detection, RKI Instruments

Frequently Asked Questions

How many gas monitoring channels does the Beacon 410A support?

The Beacon 410A supports up to four gas monitoring channels simultaneously. Each channel can be independently configured for a different gas type, alarm setpoint, and relay behavior, making it suitable for facilities that need to monitor multiple hazardous gases across different locations from a single wall-mount controller.

Does the Beacon 410A require add-on expansion cards?

No. All relays, 4-20 mA analog outputs, and Modbus digital outputs are built into the Beacon 410A as standard features. There are no add-on cards, optional modules, or additional firmware licenses to purchase—everything is included in the base unit.

What power supply options are available for the Beacon 410A?

The Beacon 410A operates from 115/220 VAC or an external 24 VDC source. An optional trickle-charging battery backup is available for the -01 and -14R variants, providing continued operation during power outages.

What sensors work with the Beacon 410A?

The Beacon 410A accepts any combination of RKI Direct Connect sensors (LEL, O2, CO2, and toxic gas variants) and any industry-standard 4-20 mA transmitter in 2-wire or 3-wire configuration. This makes the controller compatible with the full RKI sensor ecosystem as well as many third-party field transmitters.

How is the Beacon 410A configured?

All settings—alarm setpoints, relay assignments, channel type, min/max recording, and optional strobe control—are managed through the built-in OLED display using a straightforward menu system. No laptop, programming cable, or proprietary software is required for standard configuration. Contact PK Safety at 800.829.9580 if engineering support is needed for complex installations.

Specifications

  • Type
    Multi-Gas
  • Height (in.)
    8
  • Length (in.)
    13.5
  • Width (in.)
    10
  • Country of Origin
    US

Reviews

Keep your team protected & compliant!

  • Expert guidance tailored to your specific needs
  • Access responsive customer support when you need it
  • Enjoy fast shipping directly to your location
  • Benefit from extensive industry knowledge—75+ years of experience
  • In-house gas detection calibration & repair services available
The RKI Instruments Beacon 410A (Model 72-2104A) is a gray rectangular gas monitoring controller with a red and white front panel. It features a small screen, labeled buttons, and a Modbus interface, efficiently serving as a four-channel wall mount unit.
RKI Instruments

RKI Beacon 410A Four Channel Wall Mount Controller 72-2104A

From $3,421.15

RKI Beacon 410A Four Channel Wall Mount Controller is a highly configurable, microprocessor-based 4-channel gas monitoring controller. It simultaneously displays the gas type, readings, and status for four channels of gas detection and can monitor any combination of Direct Connect sensors (LEL, O2, CO2, and toxic gas sensors) as well as any 4-20 mA transmitter.

Each channel supports up to three fully configurable alarm points with two dedicated alarm relays. A bank of common relays can optionally provide up to 3 alarm relays per channel. A silenceable audible alarm, 4-20 mA analog output, and Modbus digital output are standard. A Min-Max feature retains peak readings for review at any time. All features are controlled through easy-to-navigate menus on the built-in OLED display—no laptop or external programming device required for basic configuration.

The unit operates from 115/220 VAC or 24 VDC, with an optional trickle-charging battery backup. An optional high-visibility strobe is available. The NEMA 4X enclosure resists weather and corrosion. Made in the USA.

Applications: Petrochemical plants, Refineries, Water & wastewater treatment plants, Pulp & paper mills, Gas, telephone & electric utilities, Parking garages, Manufacturing facilities, Steel, Automotive, HVAC

Key Features:

Specification Sheet:

Specification Sheet

Manual:

Manual

Part Numbers:
72-2104A - Beacon 410A, four channel controller (no sensor)
72-2104A-01 - Beacon 410A, four channel controller with battery charger (no sensors or back-up battery)
72-2104A-13R - Beacon 410A, four channel controller with large red strobe light (no sensor)
72-2104A-14R - Beacon 410A, four channel controller with battery charger terminals and large red strobe light (no sensors or back-up battery)

Related Searches
Controllers, Fixed Gas Detectors, Gas Detection, RKI Instruments

Frequently Asked Questions

How many gas monitoring channels does the Beacon 410A support?

The Beacon 410A supports up to four gas monitoring channels simultaneously. Each channel can be independently configured for a different gas type, alarm setpoint, and relay behavior, making it suitable for facilities that need to monitor multiple hazardous gases across different locations from a single wall-mount controller.

Does the Beacon 410A require add-on expansion cards?

No. All relays, 4-20 mA analog outputs, and Modbus digital outputs are built into the Beacon 410A as standard features. There are no add-on cards, optional modules, or additional firmware licenses to purchase—everything is included in the base unit.

What power supply options are available for the Beacon 410A?

The Beacon 410A operates from 115/220 VAC or an external 24 VDC source. An optional trickle-charging battery backup is available for the -01 and -14R variants, providing continued operation during power outages.

What sensors work with the Beacon 410A?

The Beacon 410A accepts any combination of RKI Direct Connect sensors (LEL, O2, CO2, and toxic gas variants) and any industry-standard 4-20 mA transmitter in 2-wire or 3-wire configuration. This makes the controller compatible with the full RKI sensor ecosystem as well as many third-party field transmitters.

How is the Beacon 410A configured?

All settings—alarm setpoints, relay assignments, channel type, min/max recording, and optional strobe control—are managed through the built-in OLED display using a straightforward menu system. No laptop, programming cable, or proprietary software is required for standard configuration. Contact PK Safety at 800.829.9580 if engineering support is needed for complex installations.

Options

  • Add Battery Charger (no sensors or back-up battery)
  • Add Large Red Strobe Light (no sensor)
  • Add Battery Charger Terminals, Large Red Strobe Light (no sensors or back-up battery)
  • Controller Only (no sensor)
View product