mPower POLI MP400P Pump 5-Gas Detector NDIR CO2/LEL/O2-LF/H2S+CO
The mPower Electronics POLI MP400P Pump 5-Gas Detector is a basic 5-gas model with built-in pump, configured with carbon dioxide (NDIR CO2), oxygen lead free (O2-LF), LEL, and carbon monoxide (CO) / Hydrogen Sulfide (H2S) combo sensor for a wide range of applications, including Confined Space Entry. With 4 sensor slots the use of combination (CO/H2S) sensors allows up to 6 gases to be measured. Contact us at 800-829-9580 for larger wireless systems with up to 32 monitors. Smart sensors carry calibration and ID information with them for quick exchange in the field during Hazmat response. The MP400P has rugged construction and easy-to-learn 2-button operation. The unique Man-Down alarm feature notifies team workers wirelessly if a user becomes incapacitated.
Applications: Industrial hygiene, Oil and gas, Fire ground "Toxic Twins" detection, Environmental, Chemical, Pharmaceutical, Telecommunications
Key Features:
- Pump version
- NDIR CO2/LEL/O2-LF/H2S+CO
- 4 Sensor slots for up to 6 gas measurements using combination sensors
- Real-time gas concentration readings
- Alarm status including Low, High, TWA, STEL and Man-Down alarms
- 6 Months continuous datalogging
- 12-Hour rechargeable Li-ion battery (pump with no wireless)
- IP-65/67 water and dust resistant case
- 360-Degree LED alarm bar; Flip screen
- Large graphical display icon-driven user interface through intuitive, simple-to-operate two-button user interface
- Easy access to pump, sensor, filter and battery
- Smart Sensors store calibration data, so they can be swapped in the field
- USB Micro charger & communications cable
- Optional POLI MonoDock station for automated bump test and calibration
- Warranty: 3 Years including sensors
Unit Includes:
- MP400P pump 4-Gas Detector NDIR CO2/LEL/O2-LF/H2S+CO
- Calibration Adaptor
- Lithium-ion Battery
- USB cable for charging & data download with 100-240V charger
- Quick Reference Guide
- Calibration Certificate
Detection target gas | Carbon dioxide (NDIR CO2) | Combustible gas (LEL%) | Oxygen lead free(O2-LF) | Hydrogen sulfide (H2S) | Carbon monoxide (CO) |
---|---|---|---|---|---|
Detection range | 50 - 50,000 ppm | 0 - 100 % LEL | 0 - 30.0 vol % | 0 - 200 ppm | 0 - 500 ppm |
Resolution | 100 ppm/td | 1 % LEL | 0.1 vol % | 0.1 ppm | 1 ppm |
Part Number:
MPA1-81A3A6-0T0L0
-
Height (in.)
-
Length (in.)
-
Width (in.)
-
Warranty Info
-
Additional Info
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.