BW Honeywell  |  SKU: BW01-CG-BUMP-B-K

BW Bump Gas Balloon Assembly Kit CG-BUMP-B-K

Ships in 4 - 6 weeks

Price $40.00
Shipping calculated at checkout.

BW Spare Balloon Assembly Kit with hose (1/8 in I.D., 3/16 in O.D.) and adaptor for bump gas is only compatible with the test gas aerosols like:

For most applications one simply sprays some gas over a unit and confirm that it works. Some units have a dedicated Bump Test mode (BWC4, ICONS) that requires a user to apply gas for a set amount of time. Some "heavy handed" users apply too much pressure and end up damaging the sensors.

It is not intended to be used with standard Calibration Gas Cylinders.

Note: H2S concentrations in bump gas cylinders degrade rapidly due to the properties of these cylinders. While these cylinders might initially come with H2S concentrations of 100 ppm, they could lose up to 60% of that concentration in 12 months (users may see only 40 ppm after 12 months). Bump gas cylinders are used for qualitative functional testing of sensors and alarms only. Bump gases cannot be used as calibration gases.

Part Number:
CG-BUMP-B-K

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Meta Pay
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Venmo
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

Depiction of the BW Bump Gas Balloon Assembly Kit CG-BUMP-B-K by BW Honeywell, featuring a blue spherical component linked to a white, curvy tube with a nozzle on top. The design is reminiscent of a traditional hand grenade combined with a medical bulb syringe, similar to equipment used for bump gas testing or monitoring H2S concentration levels.
BW Honeywell

BW Bump Gas Balloon Assembly Kit CG-BUMP-B-K

Price $40.00

BW Spare Balloon Assembly Kit with hose (1/8 in I.D., 3/16 in O.D.) and adaptor for bump gas is only compatible with the test gas aerosols like:

For most applications one simply sprays some gas over a unit and confirm that it works. Some units have a dedicated Bump Test mode (BWC4, ICONS) that requires a user to apply gas for a set amount of time. Some "heavy handed" users apply too much pressure and end up damaging the sensors.

It is not intended to be used with standard Calibration Gas Cylinders.

Note: H2S concentrations in bump gas cylinders degrade rapidly due to the properties of these cylinders. While these cylinders might initially come with H2S concentrations of 100 ppm, they could lose up to 60% of that concentration in 12 months (users may see only 40 ppm after 12 months). Bump gas cylinders are used for qualitative functional testing of sensors and alarms only. Bump gases cannot be used as calibration gases.

Part Number:
CG-BUMP-B-K

View product