mPower Electronics  |  SKU: MPE01-MP42-20112-100

mPower MUNI MP420 LEL/O2-LF/CO/HCN Gas Detector MP42-20112-100

Ships in 3 - 5 days

Price $612.56
Shipping calculated at checkout.

The mPower Electronics MUNI MP420 is a Compact and lightweight Diffusion 4-gas detector for worker safety at hazardous locations, with four standard sensors for oxygen Lead Free (O2-LF), combustibles (pellistor LEL), carbon monoxide (CO) and hydrogen cyanide (HCN). The detector is packaged in a robust housing with no moving parts. Its battery power offers 24 hrs for a standard 4-gas detector. The simple, 2-button operation results in ultimate ease of use and significantly reduced time spent training the user. To save user cost, sensors are not interchangeable and must be specified at time of purchase.

Applications: Industrial hygiene, Oil and gas, Fire ground “Toxic Twins” detection, Environmental, Chemical, Pharmaceutical, Telecommunications

Key Features:

  • Compact, robust, lightweight & wearable
  • Auto backlit LCD with large numeric digits
  • Easy-to-navigate menu with two buttons
  • Battery operation 24 hours with pellistor LEL sensor
  • Tri-color status indicators on regular self-diagnosis of sensor, battery and circuit
  • Wide angle LED alarms
  • 1000 Events log
  • Combination charge adapter / micro-USB PC interface cable
  • IP-68 weather ingress rating
  • Optional BLE wireless connectivity
  • Optional MuniDock for convenient bump & calibration
  • Up to 4 factory-configured sensors (LEL/O2-LF/CO/HCN) selected from 8 sensor options (please call Customer Service at 800-829-9580 for other options)
  • Sensors replaceable but not interchangeable (to save user cost).
  • Warranty: 2 Years including sensors

Unit Includes:

  • MP420 detector including rechargeable Li+ battery, LEL/O2-LF/CO/HCN sensors and alligator clip
  • AC Charging adapter
  • Calibration cap
  • USB Communication cable
  • Quick start guide
  • Calibration certificate
Detection target gas Combustible gas (Pellistor LEL) Oxygen Lead-Free (O2-LF) Hydrogen cyanide (HCN) Carbon monoxide (CO)
Detection range 0 - 100 % LEL 0.0 - 30.0 vol % 0 - 50 ppm 0. - 1000 ppm
Resolution 1 % LEL 0.1 vol % 0.1 ppm 1 ppm
Response time (T90) Within 15 seconds Within 15 seconds Within 45 seconds Within 15 seconds

CAUTION: Sensors are replaceable if worn out, but NOT interchangeable. Units must be ordered in the desired sensor configuration, which cannot be changed by the user.

Specification Sheet:

Specification Sheet

Quick Reference Guide:

Quick Reference Guide

Manual:

Manual

Part Number:
MP42-20112-100

Related Searches
4 Gas Diffusion Monitors, Exotic And Specialty Monitors, Gas Detection, Portable Gas Monitors And Detectors, Multi-Gas Monitors

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Venmo
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

The mPower Electronics MUNI MP420 LEL/O2-LF/CO/HCN Gas Detector (Model MP42-20112-100) is a compact and yellow portable device designed for hazardous environments. It comes equipped with a digital screen that displays levels of CO, H₂S, and additional gases. To ensure worker safety, it features control buttons beneath the screen and a secure clip on top for easy attachment.
mPower Electronics

mPower MUNI MP420 LEL/O2-LF/CO/HCN Gas Detector MP42-20112-100

Price $612.56

The mPower Electronics MUNI MP420 is a Compact and lightweight Diffusion 4-gas detector for worker safety at hazardous locations, with four standard sensors for oxygen Lead Free (O2-LF), combustibles (pellistor LEL), carbon monoxide (CO) and hydrogen cyanide (HCN). The detector is packaged in a robust housing with no moving parts. Its battery power offers 24 hrs for a standard 4-gas detector. The simple, 2-button operation results in ultimate ease of use and significantly reduced time spent training the user. To save user cost, sensors are not interchangeable and must be specified at time of purchase.

Applications: Industrial hygiene, Oil and gas, Fire ground “Toxic Twins” detection, Environmental, Chemical, Pharmaceutical, Telecommunications

Key Features:

Unit Includes:

Detection target gas Combustible gas (Pellistor LEL) Oxygen Lead-Free (O2-LF) Hydrogen cyanide (HCN) Carbon monoxide (CO)
Detection range 0 - 100 % LEL 0.0 - 30.0 vol % 0 - 50 ppm 0. - 1000 ppm
Resolution 1 % LEL 0.1 vol % 0.1 ppm 1 ppm
Response time (T90) Within 15 seconds Within 15 seconds Within 45 seconds Within 15 seconds

CAUTION: Sensors are replaceable if worn out, but NOT interchangeable. Units must be ordered in the desired sensor configuration, which cannot be changed by the user.

Specification Sheet:

Specification Sheet

Quick Reference Guide:

Quick Reference Guide

Manual:

Manual

Part Number:
MP42-20112-100

Related Searches
4 Gas Diffusion Monitors, Exotic And Specialty Monitors, Gas Detection, Portable Gas Monitors And Detectors, Multi-Gas Monitors

View product