{"product_id":"watchgas-ball-float-tubing-not-included-wg-7182112","title":"WatchGas Ball Float (Tubing NOT Included) WG-7182112","description":"\u003cp\u003e\u003cstrong\u003eA drifting sensor is a bad day. A pump full of water is a very bad day.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYour confined space clearance depends on clean, unobstructed sampling. An exposed hose opening invites disaster — dust clogs the line, liquid ingestion damages the pump, and contamination corrupts your readings. The WatchGas Ball Float stands guard. The ball floats on the water surface, and when the intake approaches water, the ball rises and blocks the opening before any liquid enters the sampling tube.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy this matters for pump-drawn sampling in wet confined spaces:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePump-drawn sampling in confined spaces routinely involves water. Wet wells, flooded vaults, tanks with residual liquid at the bottom, sumps, bilges, ballast tanks — the crew samples the atmosphere ABOVE standing water before entry. When a pump ingests water, the sampling pump can be damaged, the sensor manifold can be contaminated, and calibration is compromised. Worst case, the monitor goes silent while the crew is still relying on it — the failure isn't discovered until the next bump test. OSHA's permit-required confined space rule (29 CFR 1910.146) requires continuous monitoring during entry. A monitor whose pump is disabled by water ingestion cannot fulfill that requirement. The ball float is the low-cost accessory that protects the equipment that protects the entry.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEngineered as a single, unified piece\u003c\/strong\u003e, this ball float delivers toughness that surpasses traditional two-part designs held together by adhesive — no failure line where two halves can separate under thermal stress or repeated field use. The material resists chemicals, repels static (relevant for flammable-atmosphere sampling per API RP 2003), and refuses to absorb contaminants that would skew your measurements. Its bold yellow color cuts through shadows, keeping your equipment instantly recognizable in low-light confined-space conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat this accessory is (and isn't):\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIt IS\u003c\/strong\u003e a single-piece plastic ball float that installs at the intake end of a pump-drawn sampling tube on the \u003ca href=\"https:\/\/pksafety.com\/products\/watchgas-sst4-pump-4-gas-detector\"\u003eWatchGas SST4-PUMP 4-Gas Detector\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIt IS\u003c\/strong\u003e designed to work with 3x5mm WatchGas sampling tubing (SST-3X5-LASTOMORE) — \u003ca href=\"https:\/\/pksafety.com\/products\/watchgas-last-o-more-tubing-3x5mm-411-0018-038\"\u003esold separately by the meter\u003c\/a\u003e. Tubing is NOT included with the ball float.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIt IS\u003c\/strong\u003e part of a pump-drawn sampling ecosystem that also includes the WatchGas Demand Flow Regulator (SST-DFRPSV) for calibration workflow support — same 3x5mm tubing standard across the ecosystem.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIt is NOT\u003c\/strong\u003e compatible with the SST4-MICRO (diffusion), SST4-MINI (diffusion), or SST1 single-gas monitors. Those are diffusion monitors, not pump-drawn — no sampling tube, no ball float needed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIt is NOT\u003c\/strong\u003e a substitute for a properly-executed atmosphere-testing procedure. Continuous monitoring, bump testing, and calibration discipline still apply.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eKey features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle-piece construction\u003c\/strong\u003e — no adhesive-joined failure line, no two-half separation risk\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChemical resistance\u003c\/strong\u003e — survives contact with the mixed atmospheres and residues typical of tank entry and wastewater work\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnti-static\u003c\/strong\u003e — relevant for flammable-atmosphere sampling (API RP 2003 context)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-absorbent\u003c\/strong\u003e — does not soak up contaminants that would carry over between sampling events and skew subsequent readings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-visibility yellow\u003c\/strong\u003e — recognizable in low-light confined spaces; recoverable if dropped\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e2-year warranty\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWorks with WatchGas 3x5mm sampling tubing\u003c\/strong\u003e — sold separately (see cross-reference above)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications and deployment:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWastewater collection system entry\u003c\/strong\u003e — wet wells, headworks, junction boxes with variable water levels. Water intake is the standard hazard.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOil \u0026amp; gas tank entry\u003c\/strong\u003e (API RP 2016 workflows) — residual liquid at tank bottoms is common; sampling above it is routine.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine vessel confined-space entry\u003c\/strong\u003e — ballast tanks (water by design), bilges, engine-room sumps, cargo holds with residual water\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUtility vault entry contractors\u003c\/strong\u003e (water, sewer, storm drain, some telecom vaults) — flooded or partially-flooded vaults are common in older infrastructure\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePetroleum refinery unit shutdowns\u003c\/strong\u003e — process equipment often has residual liquid\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfined-space rescue teams\u003c\/strong\u003e — wet-space rescue is a distinct sub-discipline of confined-space rescue (NFPA 1670)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLandfill and biogas operators\u003c\/strong\u003e — gas collection infrastructure with leachate handling\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePK Safety supports the full WatchGas SST4-PUMP sampling ecosystem\u003c\/strong\u003e — the ball float, the \u003ca href=\"https:\/\/pksafety.com\/products\/watchgas-demand-flow-regulator-w-pressure-sensor-valve\"\u003eDemand Flow Regulator w\/Pressure Sensor Valve (SST-DFRPSV)\u003c\/a\u003e for calibration workflows, and the \u003ca href=\"https:\/\/pksafety.com\/products\/watchgas-last-o-more-tubing-3x5mm-sst-3x5-lastomore\"\u003eLast-O-More 3x5mm Sampling Tubing (SST-3X5-LASTOMORE)\u003c\/a\u003e for the sample-line itself. Factory-trained technicians in-house for the full WatchGas SST platform. We also service BW\/Honeywell (Factory Authorized Service Center), RKI, and RAE Systems monitors — one shop for a mixed-brand fleet's pump-drawn sampling infrastructure. Call us at \u003cstrong\u003e800.829.9580\u003c\/strong\u003e to talk through a wet-confined-space sampling workflow or to order the full three-part accessory set.\u003c\/p\u003e\n\u003cdiv class=\"specification\"\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical documents (WatchGas SST-BALL-FLOAT):\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/watchgasusa.com\/app\/uploads\/2024\/10\/WatchGas-Ball-Float-v3.2-23.10.24.pdf\" target=\"_blank\"\u003e\u003cimg border=\"0\" height=\"65\" width=\"63\" alt=\"Specification Sheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0872\/5469\/6254\/files\/pdf-icon_ac4da377-e8e0-4a9c-9dcc-746269055096.png\"\u003e\u003c\/a\u003e \u003cstrong\u003eSpecification Sheet\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e WG-7182112 — WatchGas Ball Float, single-piece, 3x5mm tubing compatible (tubing NOT included, 2-year warranty)\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdetails open=\"\"\u003e\n\u003csummary\u003eWhat does a ball float do in a pump-drawn sampling setup?\u003c\/summary\u003e\n\u003cp\u003eThe ball float is a physical safety device that prevents water and liquid ingestion into a pump-drawn gas monitor's sampling system. It sits at the far end of the sampling tube (the end that goes into the confined space, tank, or vault). When the tube's intake approaches standing water, the ball floats on the water surface. As the water rises up around the ball, the ball rises to the top of its housing and physically blocks the sampling tube's intake opening — no water enters the tube, and the pump downstream is protected.\u003c\/p\u003e\n\u003cp\u003eWithout a ball float, an accidental water intake damages the sampling pump, contaminates the sensor manifold, and often ruins calibration. The monitor may continue to display readings that appear normal but that are no longer accurate. The failure is usually discovered at the next bump test — sometimes days after the actual water intake event.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\"\u003e\n\u003csummary\u003eWhich WatchGas monitors is the SST-BALL-FLOAT compatible with?\u003c\/summary\u003e\n\u003cp\u003eThe SST-BALL-FLOAT is designed for pump-drawn sampling on the \u003ca href=\"https:\/\/pksafety.com\/products\/watchgas-sst4-pump-4-gas-detector\"\u003eWatchGas SST4-PUMP 4-Gas Detector\u003c\/a\u003e — the only pump-drawn monitor in the WatchGas SST4 family.\u003c\/p\u003e\n\u003cp\u003eIt is NOT applicable to the SST4-MICRO (diffusion), SST4-MINI (diffusion), or SST1 single-gas monitors — those monitors have no sampling tube, so no ball float is needed. If you're not certain whether your SST4 monitor is a diffusion or a pump variant, check the product label or invoice. The pump variant is explicitly named 'SST4-PUMP' — the MICRO and MINI are diffusion.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\"\u003e\n\u003csummary\u003eWhich sampling tube does the ball float work with, and is it included?\u003c\/summary\u003e\n\u003cp\u003eThe ball float is designed to fit \u003cstrong\u003e3x5mm WatchGas sampling tubing\u003c\/strong\u003e — specifically the \u003ca href=\"https:\/\/pksafety.com\/products\/watchgas-last-o-more-tubing-3x5mm-sst-3x5-lastomore\"\u003eWatchGas Last-O-More Tubing 3x5mm (SST-3X5-LASTOMORE)\u003c\/a\u003e, sold separately by the meter.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe tubing is NOT included\u003c\/strong\u003e with the ball float — the accessories are sold separately so you can specify exactly the tube length you need for your sampling depth. For most confined-space entry workflows, a 3–5 meter length is standard.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\"\u003e\n\u003csummary\u003eWhat happens if I don't use a ball float and my monitor pumps water?\u003c\/summary\u003e\n\u003cp\u003eWater in the pump-drawn sampling system typically produces one or more of these failure modes, often silently:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSampling pump damage\u003c\/strong\u003e — diaphragm pumps and micro-pumps can be damaged by liquid ingestion. Pump replacement or full monitor service may be required.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor contamination\u003c\/strong\u003e — water carries dissolved contaminants that can foul electrochemical sensor faces or the LEL sensor. The monitor may still power on but read incorrectly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCalibration drift\u003c\/strong\u003e — a contaminated sensor will fail its next bump test or calibration. Depending on severity, the sensor may need replacement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSilent failure of the monitoring workflow\u003c\/strong\u003e — the most dangerous outcome. The crew continues to rely on a monitor that appears functional but is no longer providing accurate readings. This is what OSHA 1910.146's continuous-monitoring requirement is intended to prevent, and it's what the ball float is engineered to protect against.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe $30 accessory is protecting a $980+ monitor and the confined-space entry it supports. It's one of the highest-ROI accessory purchases in the WatchGas SST catalog.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\"\u003e\n\u003csummary\u003eWhy single-piece construction instead of two-piece?\u003c\/summary\u003e\n\u003cp\u003eTraditional ball floats are often built as two half-spheres held together by adhesive. Under thermal cycling (going from cold storage to warm confined-space temperatures repeatedly), repeated field use, and exposure to chemicals in the sampled atmosphere, the adhesive bond can weaken and the two halves can separate — sometimes catastrophically at exactly the wrong moment.\u003c\/p\u003e\n\u003cp\u003eThe WatchGas ball float is engineered as a single, unified piece. No adhesive line, no two-half separation risk, no thermal-cycling failure mode. It's a durability upgrade over the industry standard.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\"\u003e\n\u003csummary\u003eHow do I attach the ball float to my sampling tube?\u003c\/summary\u003e\n\u003cp\u003eThe ball float is designed to slip-fit over the intake end of a 3x5mm WatchGas sampling tube — no adhesive, no clamp, no special tool required. The fit is engineered to be secure through normal deployment but easy to remove for cleaning or replacement between jobs.\u003c\/p\u003e\n\u003cp\u003eConsult the WatchGas Specification Sheet (linked above) for the exact assembly diagram, or call PK Safety at 800.829.9580 if you want to talk through the sampling-tube-plus-ball-float setup with a factory-trained technician.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails open=\"\"\u003e\n\u003csummary\u003eHow does the ball float fit into the full WatchGas SST4-PUMP sampling ecosystem?\u003c\/summary\u003e\n\u003cp\u003eThe pump-drawn sampling ecosystem for the SST4-PUMP includes three complementary WatchGas accessories, each sold separately:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWG-7182112\u003c\/strong\u003e (this SKU) — water intake protection at the sampling-tube intake end\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003ca href=\"https:\/\/pksafety.com\/products\/watchgas-demand-flow-regulator-w-pressure-sensor-valve\"\u003eSST-DFRPSV Demand Flow Regulator\u003c\/a\u003e\u003c\/strong\u003e — calibration workflow accessory that regulates gas flow from calibration cylinders during bump tests and full calibrations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003ca href=\"https:\/\/pksafety.com\/products\/watchgas-last-o-more-tubing-3x5mm-sst-3x5-lastomore\"\u003eSST-3X5-LASTOMORE Sampling Tubing\u003c\/a\u003e\u003c\/strong\u003e — the 3x5mm tube itself, sold by the meter for length flexibility\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor a complete confined-space sampling setup on a WatchGas SST4-PUMP, order all three. Call PK Safety at 800.829.9580 for a bundle quote.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cp\u003e\u003cstrong\u003ePlanning a wet-confined-space sampling workflow, or ordering the full SST4-PUMP sampling accessory set? Call PK Safety at 800.829.9580.\u003c\/strong\u003e A person who knows the WatchGas SST platform and pump-drawn sampling workflow will pick up.\u003c\/p\u003e","brand":"WatchGas","offers":[{"title":"Default Title","offer_id":52745837838703,"sku":"WG01-WG-7182112","price":30.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/5469\/6254\/files\/Ballfloat_no_hose800x800compressed.jpg?v=1773246226","url":"https:\/\/pksafety.com\/products\/watchgas-ball-float-tubing-not-included-wg-7182112","provider":"PK Safety Supply","version":"1.0","type":"link"}