{"product_id":"bw-flex4-gas-detector-lelf-o2-h2s-co","title":"BW Flex4 Gas Detector %LEL(F), O2, H2S, CO","description":"\u003cp\u003eProtect your team from invisible dangers. The BW Flex4 Gas Detector keeps workers safe by continuously monitoring up to four hazardous gases—combustible gases, oxygen, hydrogen sulfide, and carbon monoxide—alerting them instantly when levels exceed safe limits. With a bright light, vibration, and loud 95-decibel alarm, your crew won't miss a warning. The catalytic bead LEL sensor detects hydrogen and acetylene that infrared sensors miss, while a fine filter extends sensor life. Compact and lightweight enough for all-day wear, yet rugged enough for the toughest job sites. One charge powers up to 15 hours of continuous protection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThis is a \"Made to Order\" product that cannot be exchanged and is non-returnable. If you have any questions please call Customer Service at 800-829-9580.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Honeywell BW Flex choice of sensors:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e%LEL(F) - catalytic\u003c\/li\u003e\n\u003cli\u003eOxygen (O2)\u003c\/li\u003e\n\u003cli\u003eHydrogen Sulfide (H2S)\u003c\/li\u003e\n\u003cli\u003eCarbon Monoxide (CO)\u003c\/li\u003e\n\u003cli\u003eSulfur Dioxide (SO2)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCaution:\u003c\/strong\u003e The catalytic LEL sensor used in Honeywell BW Flex will run an average of 15 hours before needing a charge. For applications that will not detect Hydrogen or Acetylene and runs up to 60 days without needing a charge, check out the \u003ca href=\"https:\/\/pksafety.com\/products\/honeywell-bw-flex4-gas-detector-lelir-o2-h2s-co\" title=\"Honeywell BW Flex4 Gas Detector %LEL(IR), O2, H2S, CO\"\u003eBW Flex4 with the infrared type LEL sensor\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003eA catalytic bead LEL will draw more power, is susceptible to poisons that affect sensor life and needs a minimum amount of oxygen to function. The main advantage compared to the \u003ca href=\"https:\/\/pksafety.com\/products\/honeywell-bw-flex4-gas-detector-lelir-o2-h2s-co\" title=\"Honeywell BW Flex4 Gas Detector %LEL(IR), O2, H2S, CO\"\u003eBW Flex4 with the LEL Infrared sensor\u003c\/a\u003e is that catalytic bead LEL \u003cstrong\u003ewill\u003c\/strong\u003e detect Hydrogen and Acetylene. A fine filter is used on the catalytic bead LEL to prolong it’s life. The catalytic bead LEL sensors is also used in the MicroClip \u003ca href=\"https:\/\/pksafety.com\/products\/bw-honeywell-gasalert-microclip-xl-multi-gas-monitor-mcxl-xwhm-y-na\" title=\"BW Honeywell GasAlert MicroClip XL Multi-Gas Monitor, MCXL-XWHM-Y-NA\"\u003eXL\u003c\/a\u003e and \u003ca href=\"https:\/\/pksafety.com\/products\/bw-honeywell-gasalert-microclip-x3-4-gas-detector-mcx3-xwhm-y-na\" title=\"BW Honeywell GasAlert MicroClip X3 4-Gas Detector MCX3-XWHM-Y-NA\"\u003eX3\u003c\/a\u003e. A Flex with a cat bead sensor will run an average of 15 hours before needing a charge.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eReal-time gas readings at a glance\u003c\/li\u003e\n\u003cli\u003eSimultaneous monitoring of up to five gas hazards\u003c\/li\u003e\n\u003cli\u003eReliable. 2 months of battery runtime on a 4.5-hour charge — and up to 4 months if you turn off the detector at the end of each shift. No daily charging, no unexpected downtime.\u003c\/li\u003e\n\u003cli\u003eAccurate. Standard catalytic LEL sensors for complete protection over the range of traditional applications.\u003c\/li\u003e\n\u003cli\u003eResponsive. 1 Series sensors respond to dangerous gas levels in seconds, even in harsh temperatures. (for increased safety and uptime)\u003c\/li\u003e\n\u003cli\u003eEasy to use, no expertise required\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003eSmall, lightweight and wearable.\u003c\/li\u003e\n\u003cli\u003eOne-button operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003eEasy to Manage\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003eIntelliFlash green light indicates the detector is in compliance; amber light indicates the need for maintenance.\u003c\/li\u003e\n\u003cli\u003eCompatible with\u003cspan style=\"color: #3366ff;\"\u003e\u003cstrong\u003e \u003ca href=\"\/bw-intellidox-for-bw-icon-series-dx-cp\/\"\u003e\u003cspan style=\"color: #3366ff;\"\u003eIntelliDoX\u003c\/span\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e instrument management and Honeywell Safety Suite, using Bluetooth for wireless configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003eExtreme ingress protection for total confidence - stands up to dust and immersion in water.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eStandard Package Contents:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDetector complete with sensors, stainless steel alligator clip, concussion-proof housing and built-in rechargeable battery\u003c\/li\u003e\n\u003cli\u003eCalibration\/test cap and hose\u003c\/li\u003e\n\u003cli\u003eUSB charging cable\u003c\/li\u003e\n\u003cli\u003eQuick Start Guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"specification\"\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eBrochure: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0872\/5469\/6254\/files\/Flex_20Brochure_447fe038-3302-4eb8-b137-26a042bea8a1.pdf?v=1722572228\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0872\/5469\/6254\/files\/pdf-icon_ac4da377-e8e0-4a9c-9dcc-746269055096.png\" alt=\"Brochure\" width=\"63\" height=\"65\" border=\"0\"\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlex Specification Sheet: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0872\/5469\/6254\/files\/BW_20Flex_20data_sheet_223bacd7-6dac-469c-bc21-efe9c8dcbe90.pdf?v=1722572234\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0872\/5469\/6254\/files\/pdf-icon_ac4da377-e8e0-4a9c-9dcc-746269055096.png\" alt=\"Specification Sheet\" width=\"63\" height=\"65\" border=\"0\"\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlex 4\/5 Specification Sheet: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/prod-edam.honeywell.com\/content\/dam\/honeywell-edam\/sps\/hgas\/ja\/products\/portables\/honeywell-bw-flex\/documents\/hon-ia-pmc-gas-bw-flex-series-ds-rev-e-1024-en.pdf\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0872\/5469\/6254\/files\/pdf-icon_ac4da377-e8e0-4a9c-9dcc-746269055096.png\" alt=\"Specification Sheet\" width=\"63\" height=\"65\" border=\"0\"\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuick Reference Guide: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0872\/5469\/6254\/files\/BW_20Flex_20quick_reference_guide_e5ea8fe0-0b72-4121-a490-f84f78e211f8.pdf?v=1722572240\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0872\/5469\/6254\/files\/pdf-icon_ac4da377-e8e0-4a9c-9dcc-746269055096.png\" alt=\"Quick Reference Guide\" width=\"63\" height=\"65\" border=\"0\"\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eManual: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0872\/5469\/6254\/files\/BW_20Flex_20User_manual_190a6367-9b9b-47c6-8619-d33da1fb8db2.pdf?v=1722572247\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0872\/5469\/6254\/files\/pdf-icon_ac4da377-e8e0-4a9c-9dcc-746269055096.png\" alt=\"Manual\" width=\"63\" height=\"65\" border=\"0\"\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eNote: Remember to calibrate every six months and regularly perform bump tests.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFAQs:\u003c\/strong\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0872\/5469\/6254\/files\/How-Often-Do-I-Need-To-Calibrate_67fba758-c624-4b2c-9e09-248da024036b.pdf?v=1722572253\" target=\"_blank\"\u003eHow Often Do I Need To Calibrate My Gas Monitor?\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number: \u003c\/strong\u003e(for other sensor combinations, please call us at 800-829-9580.)\u003cbr\u003eCPD-W6X1H1M1-Y-00 - \u003cspan\u003e%LEL(F), O2, H2S, CO\u003c\/span\u003e\u003c\/p\u003e","brand":"BW Technologies by Honeywell","offers":[{"title":"Default Title","offer_id":52742732906863,"sku":"BW01-CPD-W6X1H1M1-Y-00","price":800.69,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/5469\/6254\/files\/sps-his-bw-flex4-render-stickers800x800compressed.jpg?v=1772641853","url":"https:\/\/pksafety.com\/products\/bw-flex4-gas-detector-lelf-o2-h2s-co","provider":"PK Safety Supply","version":"1.0","type":"link"}